# make your own in config.yaml
logLevel: info
inverter:
port: 1.2.3.4:8899 # required, port name e.g. /dev/ttyUSB0 for serial or 1.2.3.4:8899 for TCP/IP
loggerSerial: 23XXXXXXXX # required, logger serial number
readInterval: 10 # update interval in seconds, default 60
loopLogging: true # false to avoid a line to log file every readInterval
#
# if there is a non-empty attrWhiteList then only these explicitly listed attributes are output
attrWhiteList:
- ActivePower_Output_Total # Total PV generation (in units of 10W)
- ActivePower_Load_Sys # total power consumption (10W)
- ActivePower_PCC_Total # grid export (+) or import (-) (10W) = ActivePower_Output_Total - ActivePower_Load_Sys (so it is redundant data)
- Power_PV1 # PV output of string 1 (10W)
- Power_PV2 # PV output of string 2 (10W); PV1 + PV2 > ActivePower_Output_Total by about 3.5% due to inverter inefficiency?
- PV_Generation_Today # generation since midnight (10Wh)
- PV_Generation_Total
- GenerationTime_Today
- GenerationTime_Total
- Frequency_Grid
- Voltage_Phase_R # grid voltage on phase R/1
- InsulationResistance # changes to these last ones might indicate a problem
- Temperature_Env1
- Temperature_HeatSink1
# else attributes are output unless they match a regex in attrBlackList
attrBlackList:
- "^[ST]_" # prefix R_, S_, T_ for 3 phases, only R_ used in single phase systems
- "_[ST]$" # likewise suffixes _R, _S, _T
filters:
dailyGenerationSpikes: 100000 # daily generation spikes (difference between last value and current readed value) above this value (in wats) are ignored,
# here is issue which was solved by this filter https://github.com/kubaceg/Sofar-g3-lsw3-logger-reader/issues/12
mqtt: # MQTT disabled if url & prefix both blank
url: 1.2.3.4:1883 # MQTT broker URL (e.g. 1.2.3.4:1883)
user: # MQTT username (leave empty when not needed)
password: # MQTT password (leave empty when not needed)
ha_discovery_prefix: homeassistant/sensor # topic prefix for Home Assistant MQTT Discovery
state: energy/inverter/state # topic for state
otlp: # OTLP disabled if both urls blank
grpc:
url: # URL for gRPC OTLP server e.g. 0.0.0.0:4317
http:
url: # URL for HTTP OLTP server e.g. 0.0.0.0:4318
prefix: sofar.logging
# List of all attributes with non-zero values fetched from my inverter:
#
# # Most interesting to me:
# "ActivePower_Load_Sys": 16, # total power consumption (10W)
# "ActivePower_Output_Total": 333, # Total PV generation (in units of 10W)
# "ActivePower_PCC_Total": 317, # grid export (+) or import (-) (10W) = ActivePower_Output_Total - ActivePower_Load_Sys (so it is redundant data)
# "GenerationTime_Today": 553,
# "GenerationTime_Total": 54992,
# "PV_Generation_Today": 3428, # generation since midnight (10Wh)
# "PV_Generation_Total": 20355,
# # Not credible:
# "Load_Consumption_Today": 3428, # same as PV_Generation_Today, so not credible as Load
# "Load_Consumption_Total": 20355, # same as PV_Generation_Total, so not credible as Load
# # Inverter:
# "ApparentPower_Output_Total": 33,
# "Countdown": 60,
# "InsulationResistance": 1437,
# "ServiceTime_Total": 56198,
# "SysState": 2,
# "SysTime_Date": 19,
# "SysTime_Hour": 14,
# "SysTime_Minute": 56,
# "SysTime_Month": 9,
# "SysTime_Second": 1,
# "SysTime_Year": 23,
# "Temperature_Env1": 48, # Single Plate Ambient Temperature (label from SolarMan app)
# "Temperature_HeatSink1": 35, # Radiator Temperature 1 (label from SolarMan app)
# "Temperature_HeatSink2": 120, # value never seems to change
# # PV strings of panels:
# "Power_PV1": 175, # PV output of string 1 (10W)
# "Power_PV2": 172, # PV output of string 2 (10W); PV1 + PV2 > ActivePower_Output_Total by about 3.5% due to inverter inefficiency?
# "Voltage_PV1": 2438,
# "Voltage_PV2": 2436,
# "Current_PV1": 720,
# "Current_PV2": 706,
# # Grid:
# "Frequency_Grid": 5000,
# # Phase R (single phase power):
# "ActivePower_PCC_R": 317, # same as ActivePower_PCC_Total
# "Voltage_Phase_R": 2352 # grid voltage
# "Current_Output_R": 1418,
# "Current_PCC_R": 1394,