Skip to content

Latest commit

 

History

History
120 lines (118 loc) · 12.7 KB

decode_data_KTLX-G3.md

File metadata and controls

120 lines (118 loc) · 12.7 KB

KTLX-G3 data message

V5 table
1445 bytes
message type 270A

HEX DEC TYPE VALUE
0x00 0 uInt8 always a5
0x01 1 uInt16LE always 98 msg length - excl msg header(0x00 - 0x0A), checksum and last byte
0x02 2 uInt16LE always 05 msg length
0x03 3 uInt16LE always 10 msg type - data
0x04 4 uInt16LE always 42 msg type - data
0x05 5 uInt8 message nr - starts from 00(synced with server?)
0x06 6 uInt8 message nr - starts from 01
0x07 7 uInt32LE data logger SN
0x08 8 uInt32LE data logger SN
0x09 9 uInt32LE data logger SN
0x0A 10 uInt32LE data logger SN
---- --- --------
0x0B 11 uInt8 always 01
0x0C 12 uInt16LE always 0A Sensor Type List
0x0D 13 uInt16LE always 27 Sensor Type List
0x0E 14 uInt32LE total operation time (sec)
0x0F 15 uInt32LE total operation time (sec)
0x10 16 uInt32LE total operation time (sec)
0x11 17 uInt32LE total operation time (sec)
---- --- -------- --------------------------------------------------
0x50 80 int16BE inverter plate temperature (°C)
0x51 81 int16BE inverter plate temperature (°C)
---- --- -------- --------------------------------------------------
0x54 84 int16BE inverter radiator temperature (°C)
0x55 85 int16BE inverter radiator temperature (°C)
---- --- -------- --------------------------------------------------
0x78 120 uInt16BE year
0x79 121 uInt16BE year
0x7A 122 uInt16BE month
0x7B 123 uInt16BE month
0x7C 124 uInt16BE day
0x7D 125 uInt16BE day
0x7E 126 uInt16BE hour
0x7F 127 uInt16BE hour
0x80 128 uInt16BE minute
0x81 129 uInt16BE minute
0x82 130 uInt16BE second
0x83 131 uInt16BE second
---- --- -------- --------------------------------------------------
0x8E 142 string inverter SN - string(14)
0x8F 143 string inverter SN - string
0x90 144 string inverter SN - string
0x91 145 string inverter SN - string
0x92 146 string inverter SN - string
0x93 147 string inverter SN - string
0x94 148 string inverter SN - string
0x95 149 string inverter SN - string
0x96 150 string inverter SN - string
0x97 151 string inverter SN - string
0x98 152 string inverter SN - string
0x99 153 string inverter SN - string
0x9A 154 string inverter SN - string
0x9B 155 string inverter SN - string
---- --- -------- --------------------------------------------------
0xC6 198 uInt16BE frequency AC / 100 (Hz)
0xC7 199 uInt16BE frequency AC / 100 (Hz)
0xC8 200 uInt16BE currentPower / 100 (W)
0xC9 201 uInt16BE currentPower / 100 (W)
---- --- -------- --------------------------------------------------
0xD8 216 uInt16BE VAC1 / 10 (V)
0xD9 217 uInt16BE VAC1 / 10 (V)
0xDA 218 uInt16BE IAC1 / 100 (I)
0xDB 219 uInt16BE IAC1 / 100 (I)
---- --- -------- --------------------------------------------------
0xEE 238 uInt16BE VAC2 / 10 (V)
0xEF 239 uInt16BE VAC2 / 10 (V)
0xF0 240 uInt16BE IAC2 / 100 (I)
0xF1 241 uInt16BE IAC2 / 100 (I)
---- --- -------- --------------------------------------------------
0x104 260 uInt16BE VAC3 / 10 (V)
0x105 261 uInt16BE VAC3 / 10 (V)
0x106 262 uInt16BE IAC3 / 100 (I)
0x107 263 uInt16BE IAC3 / 100 (I)
---- --- -------- --------------------------------------------------
0x166 358 uInt16BE VDC1 / 10 (V)
0x167 359 uInt16BE VDC1 / 10 (V)
0x168 360 uInt16BE IDC1 / 100 (I)
0x169 361 uInt16BE IDC1 / 100 (I)
0x16A 362 uInt16BE PDC1 / 100 (W)
0x16B 363 uInt16BE PDC1 / 100 (W)
0x16C 358 uInt16BE VDC2 / 10 (V)
0x16D 359 uInt16BE VDC2 / 10 (V)
0x16E 360 uInt16BE IDC2 / 100 (I)
0x16F 361 uInt16BE IDC2 / 100 (I)
0x170 362 uInt16BE PDC2 / 100 (W)
0x171 363 uInt16BE PDC2 / 100 (W)
---- --- -------- --------------------------------------------------
0x286 646 uInt32BE daily energy / 100 (kWh)
0x287 647 uInt32BE daily energy / 100 (kWh)
0x288 648 uInt32BE daily energy / 100 (kWh)
0x289 649 uInt32BE daily energy / 100 (kWh)
0x28A 650 uInt32BE total energy / 10 (kWh)
0x28B 651 uInt32BE total energy / 10 (kWh)
0x28C 652 uInt32BE total energy / 10 (kWh)
0x28D 653 uInt32BE total energy / 10 (kWh)
---- --- -------- --------------------------------------------------
0x2D2 722 uInt16BE Bus voltage / 10 (V)
0x2D3 723 uInt16BE Bus voltage / 10 (V)
---- --- -------- --------------------------------------------------
0x2E0 736 uInt16BE combinerVoltage group 1 / 10 (V)
0x2E1 737 uInt16BE combinerVoltage group 1 / 10 (V)
0x2E2 738 uInt16BE String current group 1 / 100 (I)
0x2E3 739 uInt16BE String current group 1 / 100 (I)
---- --- -------- --------------------------------------------------
0x2E6 742 uInt16BE combinerVoltage group 2 / 10 (V)
0x2E7 743 uInt16BE combinerVoltage group 2 / 10 (V)
0x2E8 744 uInt16BE String current group 2 / 100 (I)
0x2E9 745 uInt16BE String current group 2 / 100 (I)
---- --- --------
0x5A3 162 uInt8 checksum - add all bytes, except first, last, and checksum itself, than mod 256
0x5A4 163 uInt8 always 15