Notifications
You must be signed in to change notification settings - Fork 1
/
heatingContinuous.py
168 lines (134 loc) · 4.07 KB
/
heatingContinuous.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
#!/usr/bin/python
# -*- coding: utf-8 -*-
import os
import time
import datetime
import MySQLdb as mdb
import logging
import smbus
#### Import dB Details from access.py
from access import hostname, username, password, dB
# DS1621 commands
START = 0xEE
STOP = 0x22
READ_TEMP = 0xAA
READ_COUNTER = 0xA8
READ_SLOPE = 0xA9
ACCESS_CONFIG = 0xAC
ACCESS_TH = 0xA1
ACCESS_TL = 0xA2
# read-only status bits
DONE = 0x80
TH_BIT = 0x40
TL_BIT = 0x20
NVB = 0x10 # Non-Volatile memory Busy
# r/w status bits (bit masks)
POL_HI = 0x02
POL_LO = 0xFD
ONE_SHOT = 0x01
CONT_MODE = 0xFE
CLR_TL_TH = 0x9F
##############################################
#
# Heating Controls variables
#
##############################################
logging.basicConfig(filename='/home/pi/DS1621_error.log',
level=logging.DEBUG,
format='%(asctime)s %(levelname)s %(name)s %(message)s')
logger=logging.getLogger(__name__)
# Load the modules (not required if they are loaded at boot)
# os.system('modprobe w1-gpio')
# os.system('modprobe w1-therm')
# Basic numerical assist functions
def twos_comp(byte):
'''input byte in two's complement is returned as signed integer. '''
if len(bin(byte)[2:]) > 8:
# shouldn't ever get here
print ('\nWarning: input ' + str(hex(byte)) + \
' truncated to least significant byte: ' + \
str(hex(0xFF & byte)))
byte = 0xFF & byte
return ~(255 - byte) if byte > 127 else byte
# Function for storing readings into MySQL
def insertDB(IDs, temperature):
try:
con = mdb.connect(hostname,
username,
password,
dB);
cursor = con.cursor()
for i in range(0,len(temperature)):
sql = "INSERT INTO temperature(temperature, sensor_id) \
VALUES ('%s', '%s')" % \
( temperature[i], IDs[i])
cursor.execute(sql)
sql = []
con.commit()
con.close()
except mdb.Error:
e = sys.exc_info()[0]
logger.error(e)
# routines for accessing bus data
# General read function, also updates a register
def wake_up(bus, sensor):
''' Device always starts in Idle mode, first reading is not usable.'''
read_degreesC_byte(bus, sensor)
time.sleep(0.6)
def read_degreesC_byte(bus, sensor):
'''returns temperature in degrees Celsius as integer '''
bus.read_byte_data(sensor, START)
degreesC_byte = twos_comp(bus.read_byte_data(sensor, READ_TEMP))
return degreesC_byte
def read_CHstatus(bus, sensor):
'''returns temperature in degrees Celsius as integer '''
#bus.read_byte_data(sensor, START)
try:
CHstatus = bus.read_byte(sensor)
except IOError as io_err:
print(io_err)
return(0)
return CHstatus
def write(value, address):
bus.write_byte_data(address,0,value)
return -1
def read(address):
reading = bus.read_byte(address)
return reading
################################################
#
# Start of "Main"
#
################################################
# Set up variables
address = [0x48, 0x49]
temperature = [0,0]
IDs = ["HWT_Top", "HWT_Bottom"]
# Get readings from sensors and store them in MySQL
bus = smbus.SMBus(1)
# sensorname at bus address.
print ("Starting up continuous monitor")
while True:
needToUpdate = False
for sensor in range(len(address)):
try:
wake_up(bus,address[sensor])
temp = read_degreesC_byte(bus, address[sensor])
#print (address[sensor], temp)
if temp != 0 and temp != temperature[sensor]:
#print ("Need to update dB. ", temp, temperature[sensor])
needToUpdate = True
temperature[sensor] = temp
except IOError as io_err:
currentDT = datetime.datetime.now()
print (str(currentDT))
print(io_err)
# Finished looking at each sensor. Now need to check whether we need to update the dB
if needToUpdate:
currentDT = datetime.datetime.now()
print ("Continuous. ", str(currentDT), IDs, temperature)
insertDB(IDs, temperature)
# Now check the CH system status:
# CH = read_CHstatus(bus, 0x20)
# print (hex(CH))
time.sleep(5)