Eigen system ASCII result file contains one extra time step with zero values #459

Open
lcheng9 opened this issue Mar 25, 2024 · 1 comment

Comments

@lcheng9
Copy link

lcheng9 commented Mar 25, 2024

A six-mode eigen model generates the 7th time step data in the result file. The values are zeros, seems not necessary. Thanks.

elmer_welsim.rst.txt
elmer_welsim.sif.txt
mesh.boundary.txt
mesh.element.txt
mesh.header.txt
mesh.nodes.txt

@raback
Copy link
Contributor

raback commented Jul 1, 2024

Unfortunately I was not able to reproduce the problem with these files. Btw, you may find useful to set "vtu: eigen analysis = logical true" in the Simulation section to get the eigenmodes behave as timesteps in vtu output. Then we get timesteps 0...5 in this case.