Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathgo-nut-snmpagent.go
197 lines (182 loc) · 9.32 KB
/
go-nut-snmpagent.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
// go-nut-snmpagent
// Reads MIB.nut, connects to a NUT server, and exposes a SNMP API to
//
// snmpd
//
// (c) 2023 by Gwyneth Llewelyn. All rights reserved.
// Distributed under a MIT license: https://gwyneth-llewelyn.mit-license.org/
package main
import (
"fmt"
"os"
// "github.com/posteo/go-agentx"
"github.com/posteo/go-agentx/pdu"
// "github.com/posteo/go-agentx/value"
"github.com/robbiet480/go.nut"
"gopkg.in/ini.v1"
)
// // Authentication object, which will be embedded later to reflect the INI structure.
// type GNSAuth struct {
// Username string
// Password string
// }
// GNSConfig ia a configuration object, to be filled in later.
type GNSConfig struct {
NUTserver string `validate:"ip|hostname"` // NUT server to contact.
// *GNSAuth `ini:"auth"` // I have trouble parsing sections...
Username string // Username to connect to the NUT server.
Password string // Password for the connection with NUT server.
SNMPserver string `validate:"ip|hostname"` // SNMP server to contact.
SNMPport int `validate:"integer"` // AgentX port for SNMP server (default 705).
SubagentOID string `validate:""` // OID for subagent to attach to (default PowerNet-MIB { iso org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) }).
}
type oneOID struct {
NUTvar string // NUT UPS variable name.
NUTvalue interface{} // value expressed in different possible formats (string, integer. etc.)
NUTtype pdu.VariableType // essentially to tell what type that value comes from, as per SNMP specs.
SNMPoid string // OID for this mapping (NUT var name <-> OID).
SNMPname string // Name for this mapping (e.g. PowerNet-MIB::upsHighPrecExtdBatteryTemperature)
SNMPdesc string // SNMP description of this mapping.
}
// getFirstUPS connects to NUT, authenticates and returns the first UPS listed.
func getFirstUPS(config *GNSConfig) (*nut.UPS, error) {
client, err := nut.Connect(config.NUTserver)
if err != nil {
return nil, fmt.Errorf("NUT connection error: %v", err)
}
// No authentication is perfectly valid, we just skip a step.
if config.Username != "" {
_, err = client.Authenticate(config.Username, config.Password)
if err != nil {
return nil, fmt.Errorf("NUT authentication error: %v", err)
}
} else {
fmt.Println("[DEBUG] No authentication used to connect with NUT")
}
upsList, err := client.GetUPSList()
if err != nil {
return nil, fmt.Errorf("NUT getting UPS list error: %v", err)
}
// fmt.Printf("\n[DEBUG]---------\nFirst UPS: %#v\n---------\n[/DEBUG]\n", upsList[0])
return &upsList[0], nil
}
// Everything starts here.
func main() {
// using LooseLoad so that we can simply ignore non-existing files.
cfg, err := ini.LooseLoad("config.main.ini", "config.ini")
// ,
// ini.LoadOptions{
// SkipUnrecognizableLines: true,
// })
if err != nil {
fmt.Printf("error reading configuration file: %v\n", err)
os.Exit(1)
}
// fmt.Printf("[DEBUG] Value of configuration file is: %v\n", cfg)
// place reasonable defaults into configuration struct.
// config := &GNSConfig{
// string("127.0.0.1"), // hostname
// &GNSAuth{
// Username: "",
// Password: "",
// },
// }
config := &GNSConfig{
NUTserver: "127.0.0.1", // localhost
SNMPserver: "127.0.0.1",
SNMPport: 705, // Default for AgentX connection
SubagentOID: ".1.3.6.1.4.1.318.1.1", // PowerNet-MIB { iso org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) }
Username: "",
Password: "",
}
if err = cfg.MapTo(config); err != nil {
fmt.Printf("invalid configuration, error was: %#v\n", err)
}
// fmt.Printf("[DEBUG] Value of config object is: %#v\n", config)
myUPS, err := getFirstUPS(config)
if err != nil {
fmt.Printf("could not read information of first UPS: %v\n", err)
os.Exit(2)
}
fmt.Printf("Contact with UPS %q (%s) successful.\n", myUPS.Name, myUPS.Description)
/* // debug stuff
commands, err := myUPS.GetCommands()
if err != nil {
fmt.Printf("could not read list of commands for UPS %q: %v\n", myUPS.Name, err)
} else {
fmt.Printf("Commands available for UPS %q:\n", myUPS.Name)
for _, cmd := range commands {
fmt.Printf("%s (%s)\n", cmd.Name, cmd.Description)
}
}
variables, err := myUPS.GetVariables()
if err != nil {
fmt.Printf("could not read list of variables for UPS %q: %v\n", myUPS.Name, err)
} else {
fmt.Printf("\nVariables available for UPS %q:\n", myUPS.Name)
for _, vars := range variables {
fmt.Printf("%s: %v (%s)\n", vars.Name, vars.Value, vars.Description)
}
}
*/
// We ought to do some magic mapping between the MIB and the NUT variables... they do not exactly overlap
var oneMap = &[]oneOID{
{"battery.charge", 100, pdu.VariableTypeInteger, "", "", ""},
{"battery.charge.low", 10, pdu.VariableTypeInteger, "", "", ""},
{"battery.charge.warning", 50, pdu.VariableTypeInteger, "", "", ""},
{"battery.mfr.date", "2022/02/18", pdu.VariableTypeOctetString, "", "", ""}, // date YYYY/MM/DD
{"battery.runtime", 3720, pdu.VariableTypeInteger, ".1.1.1.2.2.3.0", "", "The UPS battery run time remaining before battery exhaustion."},
{"battery.runtime.low", 120, pdu.VariableTypeInteger, "", "", ""},
{"battery.temperature", 270, pdu.VariableTypeInteger, ".1.1.1.2.3.13.0", "PowerNet-MIB::upsHighPrecExtdBatteryTemperature", "The current internal UPS temperature expressed in tenths of degrees Celsius. Can be negative."}, // divide by 10
{"battery.type", "PbAc", pdu.VariableTypeOctetString, "", "", ""},
{"battery.voltage", 275, pdu.VariableTypeInteger, "", "", ""}, // divide by 10
{"battery.voltage.nominal", 240, pdu.VariableTypeInteger, "", "", ""}, // divide by 10
{"device.mfr", "American Power Conversion", pdu.VariableTypeOctetString, "", "", ""},
{"device.model", "Smart-UPS 1000", pdu.VariableTypeOctetString, "", "", ""},
{"device.serial", "AS0632330748", pdu.VariableTypeOctetString, "", "", ""},
{"device.type", "ups", pdu.VariableTypeOctetString, "", "", ""},
{"driver.name", "usbhid-ups", pdu.VariableTypeOctetString, "", "", ""},
{"driver.parameter.bus", "001", pdu.VariableTypeOctetString, "", "", ""},
{"driver.parameter.pollfreq", 30, pdu.VariableTypeInteger, "", "", ""},
{"driver.parameter.pollinterval", 2, pdu.VariableTypeInteger, "", "", ""},
{"driver.parameter.port", "auto", pdu.VariableTypeOctetString, "", "", ""},
{"driver.parameter.product", "Smart-UPS 1000 FW:652.13.I USB FW:7.3", pdu.VariableTypeOctetString, "", "", ""},
{"driver.parameter.productid", "0002", pdu.VariableTypeOctetString, "", "", ""},
{"driver.parameter.serial", "AS0632330748", pdu.VariableTypeOctetString, "", "", ""},
{"driver.parameter.synchronous", "no", pdu.VariableTypeOctetString, "", "", ""},
{"driver.parameter.vendor", "American Power Conversion", pdu.VariableTypeOctetString, "", "", ""},
{"driver.parameter.vendorid", "051D", pdu.VariableTypeOctetString, "", "", ""},
{"driver.version", "2.7.4", pdu.VariableTypeOctetString, "", "", ""},
{"driver.version.data", "APC HID 0.96", pdu.VariableTypeOctetString, "", "", ""},
{"driver.version.internal", "0.41", pdu.VariableTypeOctetString, "", "", ""},
{"input.sensitivity", "medium", pdu.VariableTypeOctetString, "", "", ""},
{"input.transfer.high", 2530, pdu.VariableTypeInteger, "", "", ""}, //divide by 10
{"input.transfer.low", 2080, pdu.VariableTypeInteger, "", "", ""},// divide by 10
{"input.voltage", 2260, pdu.VariableTypeInteger, ".1.1.1.3.2.1.0", "", "The current utility line voltage in VAC."}, // divide by 10
{"output.current", 46, pdu.VariableTypeInteger, "", "", ""}, // divide by 100
{"output.frequency", 500, pdu.VariableTypeInteger, "", "", ""}, // divide by 10
{"output.voltage", 2260, pdu.VariableTypeInteger, ".1.1.1.4.2.1.0", "", "The output voltage of the UPS system in VAC."}, // divide by 10
{"output.voltage.nominal", 2300, pdu.VariableTypeInteger, "", "", ""}, // divide by 10
{"ups.beeper.status", "disabled", pdu.VariableTypeOctetString, "", "", ""},
{"ups.delay.shutdown", 20, pdu.VariableTypeInteger, "", "", ""},
{"ups.delay.start", 30, pdu.VariableTypeInteger, "", "", ""},
{"ups.firmware", "652.13.I", pdu.VariableTypeOctetString, "", "", ""},
{"ups.firmware.aux", "7.3", pdu.VariableTypeOctetString, "", "", ""},
{"ups.load", 169, pdu.VariableTypeGauge32, ".1.1.1.4.2.3.0", "", "The current UPS load expressed in percent of rated capacity."}, // divide by 10
{"ups.mfr", "American Power Conversion", pdu.VariableTypeOctetString, "", "", ""},
{"ups.mf22r.date", "2006/08/03", pdu.VariableTypeOctetString, "", "", ""}, // date YYYY/MM/DD
{"ups.model", "Smart-UPS 1000", pdu.VariableTypeOctetString, "", "", ""},
{"ups.productid", "0002", pdu.VariableTypeOctetString, "", "", ""},
{"ups.serial", "AS0632330748", pdu.VariableTypeOctetString, "", "", ""},
{"ups.status", "OL", pdu.VariableTypeOctetString, "", "", ""},
{"ups.test.result", "No test initiated", pdu.VariableTypeOctetString, "", "", ""},
{"ups.timer.reboot", -1, pdu.VariableTypeInteger, "", "", ""},
{"ups.timer.shutdown", -1, pdu.VariableTypeInteger, "", "", ""},
{"ups.timer.start", -1, pdu.VariableTypeInteger, "", "", ""},
{"ups.vendorid", "051d", pdu.VariableTypeOctetString, "", "", ""},
}
fmt.Println("NUT var name\tValue\tType\tOID Name Description")
for _, apcRawData := range *oneMap {