Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathpac3200_template.yaml
560 lines (560 loc) · 20 KB
/
pac3200_template.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
zabbix_export:
version: '6.4'
template_groups:
- uuid: a37aa5a7dc9248608392f769580388e5
name: Powermeter
templates:
- uuid: 800881be52814d299f3dfb1bb75d2e42
template: 'Template PAC3200 Powermeter modbus'
name: 'Template PAC3200 Powermeter modbus'
groups:
- name: Powermeter
items:
- uuid: c5196d11063b496a8c6ba76bd143452a
name: 'Template PAC3200 readings 1-32'
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
delay: 30s
trends: '0'
value_type: TEXT
description: PAC3200
tags:
- tag: Application
value: PowerMeter
- uuid: ab1eef04c86a4dfe8124d73f49bb3202
name: 'Template PAC3200 readings 33-64'
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_33_64},{$MODBUS_COUNT_33_64},{$MODBUS_TYPE}]'
delay: 30s
history: 7d
trends: '0'
value_type: TEXT
description: PAC3200
tags:
- tag: Application
value: PowerMeter
- uuid: c1dedad7b2f6461898d0c57dd57c8194
name: 'Template PAC3200 energy readings'
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_ENERGY},{$MODBUS_COUNT_ENERGY},{$MODBUS_TYPE}]'
delay: 10m
history: 7d
trends: '0'
value_type: TEXT
tags:
- tag: Application
value: PowerMeter
- uuid: b0142e0d1f524ffa876523f9e68f1f92
name: 'Template PAC3200 Active Energy Export Tariff 1'
type: DEPENDENT
key: pac3200_Active_Energy_Export_Tariff_1
delay: '0'
history: 7d
value_type: FLOAT
units: Wh
preprocessing:
- type: JSONPATH
parameters:
- '$[2]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_ENERGY},{$MODBUS_COUNT_ENERGY},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 062a0c2328f84159baefb2417d526b89
name: 'Template PAC3200 Active Energy Export Tariff 2'
type: DEPENDENT
key: pac3200_Active_Energy_Export_Tariff_2
delay: '0'
history: 7d
value_type: FLOAT
units: Wh
preprocessing:
- type: JSONPATH
parameters:
- '$[3]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_ENERGY},{$MODBUS_COUNT_ENERGY},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 5a892093e97e4b3787836d15540d2b52
name: 'Template PAC3200 Active Energy Import Tariff 1'
type: DEPENDENT
key: pac3200_Active_Energy_Import_Tariff_1
delay: '0'
history: 7d
value_type: FLOAT
units: Wh
preprocessing:
- type: JSONPATH
parameters:
- '$[0]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_ENERGY},{$MODBUS_COUNT_ENERGY},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: f231a96b7200436cb1027f98e352a0e7
name: 'Template PAC3200 Active Power a'
type: DEPENDENT
key: pac3200_Active_Power_a
delay: '0'
history: 7d
value_type: FLOAT
units: W
preprocessing:
- type: JSONPATH
parameters:
- '$[12]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 642998d8bf624f1faf554655ab2d0abb
name: 'Template PAC3200 Active Power b'
type: DEPENDENT
key: pac3200_Active_Power_b
delay: '0'
history: 7d
value_type: FLOAT
units: W
preprocessing:
- type: JSONPATH
parameters:
- '$[13]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: bdd97b5dac724f47ab863ae1e339ea46
name: 'Template PAC3200 Active Power c'
type: DEPENDENT
key: pac3200_Active_Power_c
delay: '0'
history: 7d
value_type: FLOAT
units: W
preprocessing:
- type: JSONPATH
parameters:
- '$[14]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 95336a88e45a414ea51ff46e1dd62156
name: 'Template PAC3200 Apparent Energy Tariff 1'
type: DEPENDENT
key: pac3200_Apparent_Energy_Tariff_1
delay: '0'
history: 7d
value_type: FLOAT
units: VAh
preprocessing:
- type: JSONPATH
parameters:
- '$[8]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_ENERGY},{$MODBUS_COUNT_ENERGY},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 42c0193410ba485782db8b4cb87882cb
name: 'Template PAC3200 Apparent Energy Tariff 2'
type: DEPENDENT
key: pac3200_Apparent_Energy_Tariff_2
delay: '0'
history: 7d
value_type: FLOAT
units: VAh
preprocessing:
- type: JSONPATH
parameters:
- '$[9]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_ENERGY},{$MODBUS_COUNT_ENERGY},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: fe9e5bfea24f42c6a7d64970a853bf81
name: 'Template PAC3200 Apparent Power a'
type: DEPENDENT
key: pac3200_Apparent_Power_a
delay: '0'
history: 7d
value_type: FLOAT
units: VA
preprocessing:
- type: JSONPATH
parameters:
- '$[9]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 89765d53c2a14f0eb399ab5465004d6f
name: 'Template PAC3200 Apparent Power b'
type: DEPENDENT
key: pac3200_Apparent_Power_b
delay: '0'
history: 7d
value_type: FLOAT
units: VA
preprocessing:
- type: JSONPATH
parameters:
- '$[10]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 64071eb58b794f62b82ca435ad052cc3
name: 'Template PAC3200 Apparent Power c'
type: DEPENDENT
key: pac3200_Apparent_Power_c
delay: '0'
history: 7d
value_type: FLOAT
units: VA
preprocessing:
- type: JSONPATH
parameters:
- '$[11]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: c451bfd318384b2c8a90ccdbf5b2f781
name: 'Template PAC3200 Current a'
type: DEPENDENT
key: pac3200_Current_a
delay: '0'
history: 7d
value_type: FLOAT
units: A
preprocessing:
- type: JSONPATH
parameters:
- '$[6]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 216ff1c4d815460a900a2e3a17138a3b
name: 'Template PAC3200 Current b'
type: DEPENDENT
key: pac3200_Current_b
delay: '0'
history: 7d
value_type: FLOAT
units: A
preprocessing:
- type: JSONPATH
parameters:
- '$[7]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: d812991bec904807ac6152e9bcb23a66
name: 'Template PAC3200 Current c'
type: DEPENDENT
key: pac3200_Current_c
delay: '0'
history: 7d
value_type: FLOAT
units: A
preprocessing:
- type: JSONPATH
parameters:
- '$[8]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 38f83f58b02d42cb8c2839bab3e77ac1
name: 'Template PAC3200 Power Factor a'
type: DEPENDENT
key: pac3200_Power_Factor_a
delay: '0'
history: 7d
value_type: FLOAT
preprocessing:
- type: JSONPATH
parameters:
- '$[18]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 15e48dab14094985b4eb8993a29a5aba
name: 'Template PAC3200 Power Factor b'
type: DEPENDENT
key: pac3200_Power_Factor_b
delay: '0'
history: 7d
value_type: FLOAT
preprocessing:
- type: JSONPATH
parameters:
- '$[20]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: bad951706da74583a08c7639aac3c057
name: 'Template PAC3200 Power Factor c'
type: DEPENDENT
key: pac3200_Power_Factor_c
delay: '0'
history: 7d
value_type: FLOAT
preprocessing:
- type: JSONPATH
parameters:
- '$[20]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: b0d3ca7ecba54a58b17c97337017b2ff
name: 'Template PAC3200 Power Frequency'
type: DEPENDENT
key: pac3200_Power_Frequency
delay: '0'
history: 7d
value_type: FLOAT
preprocessing:
- type: JSONPATH
parameters:
- '$[28]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: cab11358eeb04ff1a58014a8a22efd2d
name: 'Template PAC3200 Reactive Energy Export Tariff 1'
type: DEPENDENT
key: pac3200_Reactive_Energy_Export_Tariff_1
delay: '0'
history: 7d
value_type: FLOAT
units: varh
preprocessing:
- type: JSONPATH
parameters:
- '$[6]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_ENERGY},{$MODBUS_COUNT_ENERGY},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: af013165f9594c4e869c632d84e7f097
name: 'Template PAC3200 Reactive Energy Import Tariff 1'
type: DEPENDENT
key: pac3200_Reactive_Energy_Import_Tariff_1
delay: '0'
history: 7d
value_type: FLOAT
units: varh
preprocessing:
- type: JSONPATH
parameters:
- '$[4]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_ENERGY},{$MODBUS_COUNT_ENERGY},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 9a0c631aeb75473292328d9a070710c4
name: 'Template PAC3200 Reactive Energy Import Tariff 2'
type: DEPENDENT
key: pac3200_Reactive_Energy_Import_Tariff_2
delay: '0'
history: 7d
value_type: FLOAT
units: varh
preprocessing:
- type: JSONPATH
parameters:
- '$[5]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_ENERGY},{$MODBUS_COUNT_ENERGY},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 02b4527c06c54aaaa6473f9e9a0d24a4
name: 'Template PAC3200 Reactive Power a'
type: DEPENDENT
key: pac3200_Reactive_Power_a
delay: '0'
history: 7d
value_type: FLOAT
units: varh
preprocessing:
- type: JSONPATH
parameters:
- '$[15]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 49e0f8870c6d42bab9c6ad7bc54895a9
name: 'Template PAC3200 Reactive Power b'
type: DEPENDENT
key: pac3200_Reactive_Power_b
delay: '0'
history: 7d
value_type: FLOAT
units: varh
preprocessing:
- type: JSONPATH
parameters:
- '$[16]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: a837a7651d1f45328a55fa41f883facb
name: 'Template PAC3200 Reactive Power c'
type: DEPENDENT
key: pac3200_Reactive_Power_c
delay: '0'
history: 7d
value_type: FLOAT
units: varh
preprocessing:
- type: JSONPATH
parameters:
- '$[17]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: ff46f386d2ae477db739c68bcc3a2b6b
name: 'Template PAC3200 Total Active Power'
type: DEPENDENT
key: pac3200_Total_Active_Power
delay: '0'
history: 7d
value_type: FLOAT
units: W
preprocessing:
- type: JSONPATH
parameters:
- '$[0]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_33_64},{$MODBUS_COUNT_33_64},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 4200b5b877cc41fc9f9f3af50199e4e3
name: 'Template PAC3200 Total Apparent Power'
type: DEPENDENT
key: pac3200_Total_Apparent_Power
delay: '0'
history: 7d
value_type: FLOAT
units: VA
preprocessing:
- type: JSONPATH
parameters:
- '$[31]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: aaf7238d657c45fe9d3182c7da1fb95d
name: 'Template PAC3200 Voltage Va-n'
type: DEPENDENT
key: pac3200_Voltage_Va-n
delay: '0'
history: 7d
value_type: FLOAT
units: V
preprocessing:
- type: JSONPATH
parameters:
- '$[0]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: 2d63a56060534471b06ef1dac3f4a6de
name: 'Template PAC3200 Voltage Vb-n'
type: DEPENDENT
key: pac3200_Voltage_Vb-n
delay: '0'
history: 7d
value_type: FLOAT
units: V
preprocessing:
- type: JSONPATH
parameters:
- '$[1]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
- uuid: f322ae4a5b4f4db98842ba0a3147f589
name: 'Template PAC3200 Voltage Vc-n'
type: DEPENDENT
key: pac3200_Voltage_Vc-n
delay: '0'
history: 7d
value_type: FLOAT
units: V
preprocessing:
- type: JSONPATH
parameters:
- '$[2]'
master_item:
key: 'modbus.get[tcp://{$MODBUS_ENDPOINT},{$MODBUS_SLAVEID},{$MODBUS_FUNCTION},{$MODBUS_ADDRESS_1_32},{$MODBUS_COUNT_1_32},{$MODBUS_TYPE}]'
tags:
- tag: Application
value: PowerMeter
macros:
- macro: '{$MODBUS_ADDRESS}'
value: '801'
- macro: '{$MODBUS_ADDRESS_1_12}'
value: '1'
- macro: '{$MODBUS_ADDRESS_1_32}'
value: '1'
- macro: '{$MODBUS_ADDRESS_33_64}'
value: '65'
- macro: '{$MODBUS_ADDRESS_ENERGY}'
value: '801'
- macro: '{$MODBUS_COUNT}'
value: '10'
- macro: '{$MODBUS_COUNT_1_12}'
value: '12'
- macro: '{$MODBUS_COUNT_1_32}'
value: '32'
- macro: '{$MODBUS_COUNT_33_64}'
value: '32'
- macro: '{$MODBUS_COUNT_ENERGY}'
value: '10'
- macro: '{$MODBUS_ENDPOINT}'
- macro: '{$MODBUS_FUNCTION}'
value: '3'
- macro: '{$MODBUS_SLAVEID}'
value: '1'
- macro: '{$MODBUS_TYPE}'
value: double