Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathbme280-logger.fs
executable file
·212 lines (162 loc) · 6.34 KB
/
bme280-logger.fs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
Marker bme280-logger.fs .latest
8 constant /location
create extension$ ," .bme280"
yearToday value InitialYear
20 newuser filename$
: (SetFilename ( year - )
(.) filename$ place extension$ count filename$ +place ;
0 value FileError
: SetFilename ( year - )
(SetFilename filename$ count file-status nip
if yearToday (SetFilename true to FileError
then ;
: SetFileYearToday ( - ) yearToday SetFilename ;
SetFileYearToday \ Name of the logfile. Eg: 2017.bme280
0 value &bme280Record
begin-structure /bme280Record \ The definition of ONE INLINE record
lfield: >Date
lfield: >Time
lfield: >Location \ counted string
xfield: >Pressure
xfield: >Temperature
xfield: >Humidity
xfield: >Pollution
xfield: >Light
end-structure
/bme280Record dup here swap allot dup to &bme280Record swap erase
: SetLocation ( str adr -- ) /location 1- min &bme280Record >Location place ;
s" Kamer" SetLocation
: DateTimeCode ( d m Y - ymmdd ) 10000 * swap 100 * + + ;
: .bme280Record ( &bme280Record - )
cr
dup >Date ? space
dup >Time ? space
dup >Location count type space
dup >Pressure f@ f. space
dup >Temperature f@ f. space
dup >Humidity f@ f. space
dup >Pollution f@ f. space
>Light f@ f. space ;
: OpenCreateLogfile ( - file-id )
filename$ count 2dup file-status nip 0<>
if r/w bin create-file throw
else r/w bin open-file throw
dup dup file-size throw
rot reposition-file throw
then ;
Samples: PressureSamples
Samples: TemperatureSamples
Samples: HumiditySamples
Samples: PollutionSamples
Samples: LdrSamples
[UNDEFINED] Bme280>f [IF] : Bme280>f ( ref - ) ( f: - t h p ) drop 0e0 0e0 0e0 ; [THEN]
: OnNewYear ( - ) \ Creates each year a new logfile
InitialYear yearToday <>
if yearToday dup to InitialYear SetFilename
OpenCreateLogfile CloseFile
then ;
60 1000 * #samples / constant SampleTime
: takeSample ( fd-Bme280 - )
dup 0<>
if Bme280>f PressureSamples sample!
TemperatureSamples sample!
HumiditySamples sample!
else drop \ For NON BME280 sensors: Point deferred sensor so it return a float from that sensor.
PressureSensor PressureSamples sample!
TemperatureSensor TemperatureSamples sample!
HumiditySensor HumiditySamples sample!
then
WiFiBitRate@|Mq135f@ PollutionSamples sample!
WiFiSignalLeve@|Ldrf@% LdrSamples sample!
incr-sample ;
false value \Overshoot \ Change \Overshoot into true to see the time after 10 samples
2000 constant overshoot \ Time in MS passed 1 minute after taking 10 samples on my system
60 1000 * overshoot - constant MsTimeout
\ MsTimeout #samples * .
: RunningSampletime ( - RunningSampletime )
MsTimeout time&date drop 2drop 2drop 1000 * - #samples /
[ overshoot 10 / 1 max ] literal max ;
: SaveTime ( - )
time&date DateTimeCode &bme280Record >Date ! DateTimeCode &bme280Record >Time ! ;
: SeeOvershoot ( - )
\Overshoot
if postpone cr postpone .time
else exit
then ; immediate
: takeSamples ( fd-Bme280 - )
RunningSampletime SaveTime
#samples 0
do over takeSample dup ms
loop 2drop SaveTime
SeeOvershoot
PressureSamples AverageSamples &bme280Record >Pressure f!
TemperatureSamples AverageSamples &bme280Record >Temperature f!
HumiditySamples AverageSamples &bme280Record >Humidity f!
PollutionSamples AverageSamples &bme280Record >Pollution f!
LdrSamples AverageSamples &bme280Record >Light f! ;
: FileRecords ( fd-Bme280 - )
begin OnNewYear
dup takeSamples
OpenCreateLogfile \ It seems it is not save to extend or write to a file when it is mapped.
&bme280Record >Pressure f@ &bme280Record >Humidity f@ f+ 0e f>
if &bme280Record >Date /bme280Record 2 pick write-file throw
\ dup flush-file drop \ cr .InlineRec
else cr (date) type space .time ." Invalid record"
then
CloseFile
again ;
: (LogValues ( - )
[defined] initMcp3008
[if] CheckSPI
if initMcp3008 fdBme280 dup ChipId@ 0<
if drop 0
then
else 0
then
[else] 0
[then]
FileRecords ;
0 value TidLogValues
: LogValues ( - )
stacksize4 newtask4 dup to TidLogValues activate (LogValues ;
variable &bme280-FileRecords \ Pointer to the records in the logfile
: r>bme280-FileRecord ( n - &FileRecord ) \ Pointer to 1 record in the logfile
/bme280Record * &bme280-FileRecords @ + ;
\ For the various fields in one record in the logfile:
: r>DateBme280 ( n - addr ) r>bme280-FileRecord >Date ;
: r>TimeBme280 ( n - addr ) r>bme280-FileRecord >Time ;
: r>Location ( n - addr ) r>bme280-FileRecord >Location ;
: r>Pressure ( n - addr ) r>bme280-FileRecord >Pressure ;
: r>Temperature ( n - addr ) r>bme280-FileRecord >Temperature ;
: r>Humidity ( n - addr ) r>bme280-FileRecord >Humidity ;
: r>Pollution ( n - addr ) r>bme280-FileRecord >Pollution ;
: r>Light ( n - addr ) r>bme280-FileRecord >Light ;
: GetTemperature ( - temp*10 ) &bme280Record >Temperature f@ 10e f* f>s ;
ALSO HTML
' r>TimeBme280 is r>Time
' r>DateBme280 is r>Date
1 cells newuser #records
1 cells newuser record-size
1 cells newuser Bme280Hndl
PREVIOUS
: MapFid ( fid -- addr u ) \ For older Gforth versions
>r r@ file-size throw d>s 0 over PROT_RW MAP_SHARED r@ fileno 0 mmap
dup ?ior swap r> CloseFile ;
: MapBme280Data ( -- vadr count|0 )
filename$ count 2dup file-status nip
if 2drop 0 0
else r/w open-file throw dup Bme280Hndl ! MapFid
over &bme280-FileRecords !
dup /bme280Record dup record-size ! / 1- 0 max #records !
then ;
: UnMapBme280Data ( vadr count|0 -- )
dup
if unmap-file
else 2drop
then ;
\Overshoot [if] cr .( Wait at least 2 minutes) cr (LogValues abort [then]
\\\
\ InitBme280 cr bme280_i2c_address cr .( I2c addres: ) h. dup 2 spaces .ChipId .bme280
1 .interval
\ 1 .CsvRecords
\\\