DIGI IN 2 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.
- Author : Stefan Ilic
- Date : Dec 2023.
- Type : SPI type
This example demonstrates the use of DIGI IN 2 Click board by reading and displaying the state of the channels.
- MikroSDK.Board
- MikroSDK.Log
- Click.DIGIIN2
digiin2_cfg_setup
Config Object Initialization function.
void digiin2_cfg_setup ( digiin2_cfg_t *cfg );
digiin2_init
Initialization function.
err_t digiin2_init ( digiin2_t *ctx, digiin2_cfg_t *cfg );
digiin2_default_cfg
Click Default Configuration function.
err_t digiin2_default_cfg ( digiin2_t *ctx );
digiin2_get_flt_pin
This function is used to get state of the FLT pin.
uint8_t digiin2_get_flt_pin ( digiin2_t *ctx );
digiin2_write_reg
This function is used to write data into the selected register by using SPI serial interface.
err_t digiin2_write_reg ( digiin2_t *ctx, uint8_t reg, uint8_t data_in );
digiin2_read_reg
This function reads a data byte from the selected register by using SPI serial interface.
err_t digiin2_read_reg ( digiin2_t *ctx, uint8_t reg, uint8_t *data_out );
Initializes the driver, performs the Click default configuration.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
digiin2_cfg_t digiin2_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
digiin2_cfg_setup( &digiin2_cfg );
DIGIIN2_MAP_MIKROBUS( digiin2_cfg, MIKROBUS_1 );
if ( SPI_MASTER_ERROR == digiin2_init( &digiin2, &digiin2_cfg ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
if ( DIGIIN2_ERROR == digiin2_default_cfg ( &digiin2 ) )
{
log_error( &logger, " Default configuration." );
for ( ; ; );
}
log_info( &logger, " Application Task " );
}
Reads and displays on the USB UART the channel state every second.
void application_task ( void )
{
uint8_t channel_data = 0;
digiin2_pulse_latch( &digiin2 );
if ( DIGIIN2_OK == digiin2_read_reg( &digiin2, DIGIIN2_REG_DISTATE, &channel_data ) )
{
if ( channel_data & DIGIIN2_CHANNEL_1_MASK )
{
log_printf( &logger, "Channel 1 counter: HIGH \r\n" );
}
else
{
log_printf( &logger, "Channel 1 counter: LOW \r\n" );
}
if ( channel_data & DIGIIN2_CHANNEL_2_MASK )
{
log_printf( &logger, "Channel 2 counter: HIGH \r\n" );
}
else
{
log_printf( &logger, "Channel 2 counter: LOW \r\n" );
}
if ( channel_data & DIGIIN2_CHANNEL_3_MASK )
{
log_printf( &logger, "Channel 3 counter: HIGH \r\n" );
}
else
{
log_printf( &logger, "Channel 3 counter: LOW \r\n" );
}
if ( channel_data & DIGIIN2_CHANNEL_4_MASK )
{
log_printf( &logger, "Channel 4 counter: HIGH \r\n" );
}
else
{
log_printf( &logger, "Channel 4 counter: LOW \r\n" );
}
if ( channel_data & DIGIIN2_CHANNEL_5_MASK )
{
log_printf( &logger, "Channel 5 counter: HIGH \r\n" );
}
else
{
log_printf( &logger, "Channel 5 counter: LOW \r\n" );
}
if ( channel_data & DIGIIN2_CHANNEL_6_MASK )
{
log_printf( &logger, "Channel 6 counter: HIGH \r\n" );
}
else
{
log_printf( &logger, "Channel 6 counter: LOW \r\n" );
}
if ( channel_data & DIGIIN2_CHANNEL_7_MASK )
{
log_printf( &logger, "Channel 7 counter: HIGH \r\n" );
}
else
{
log_printf( &logger, "Channel 7 counter: LOW \r\n" );
}
if ( channel_data & DIGIIN2_CHANNEL_8_MASK )
{
log_printf( &logger, "Channel 8 counter: HIGH \r\n" );
}
else
{
log_printf( &logger, "Channel 8 counter: LOW \r\n" );
}
log_printf( &logger, "- - - - - - - - - - - - - -\r\n" );
}
else
{
log_error( &logger, " Read error." );
}
if ( DIGIIN2_PIN_STATE_HIGH == digiin2_get_flt_pin( &digiin2 ) )
{
uint8_t flt_data = 0;
digiin2_read_reg( &digiin2, DIGIIN2_REG_FAULT, &flt_data );
log_printf( &logger, "Fault1 data: 0x%.2X \r\n", ( uint16_t ) flt_data );
digiin2_read_reg( &digiin2, DIGIIN2_REG_FAULT2, &flt_data );
log_printf( &logger, "Fault2 data: 0x%.2X \r\n", ( uint16_t ) flt_data );
log_printf( &logger, "- - - - - - - - - - - - - -\r\n" );
}
Delay_ms ( 1000 );
}
This Click board can be interfaced and monitored in two ways:
- Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
- UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.
The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.