This is rather a question: Do the NXcollection groups 'camera_parameters' and 'image_preprocessing' relate to the 'image' field of the instrument/detector group?
If so, I would recommend to shift these NXcollection groups to the instrument/detector group. Moreover, check if any of these terms can be translated/mapped to predefined NeXus terms, e.g.
camera_parameters/exposuretimeabs to NeXus terms '/entry/instrument/detector/real_time' or '/entry/instrument/detector/count_time', respectively.
camera_parameters/gain or camera_parameters/gain_auto to the NeXus term '/entry/instrument/detector/gain_setting', if applicable.
The text was updated successfully, but these errors were encountered:
Yes, the NXcollection groups "camera_parameters" and "image_preprocessing" refer to the "image". It is a good idea to move these to the detector.
Q for preprocessing: how I can link to a background image? Where BG image should be stored? I don't like to store it with each measurement.
Regarding exptime <-> real_time: it only makes sense if I would specify a mapping rule. For me it is not intuitive to link real_time with exposuretime.
One way or another, we need an extension for measuring devices. Even for cameras, there are a lot of parameters that certainly cannot be mapped to NeXus predefined terms
UPDATE:
if I understand NXdetector manualcorrectly, most close parameter to exposuretime is the count-time.
how I can link to a background image? Where BG image should be stored? I don't like to store it with each measurement.
In NXdetector it is intended to store the background image with your sample measurements but setting 'image_key'=4. If you want to store the background image separately, you could add another NXdetector with separate data field and separate 'image_key'=4 for the background image (or a link to NXdetector of another NXentry containing the background measurement). Would that fit?
This is rather a question: Do the NXcollection groups 'camera_parameters' and 'image_preprocessing' relate to the 'image' field of the instrument/detector group?
If so, I would recommend to shift these NXcollection groups to the instrument/detector group. Moreover, check if any of these terms can be translated/mapped to predefined NeXus terms, e.g.