//module Control(Op,WB, M, EX,j,bne,imm,andi,ori,addi);
module Control(
input [5:0] Op,
output[8:0] Out
//,output j,bne,imm,andi,ori,addi;
);
wire regdst,alusrc,memtoreg,regwrite,memread,memwrite,branch;
//determines type of instruction
wire r = ~Op[5]&~Op[4]&~Op[3]&~Op[2]&~Op[1]&~Op[0];
wire lw = Op[5]&~Op[4]&~Op[3]&~Op[2]&Op[1]&Op[0];
wire sw = Op[5]&~Op[4]&Op[3]&~Op[2]&Op[1]&Op[0];
wire beq = ~Op[5]&~Op[4]&~Op[3]&Op[2]&~Op[1]&~Op[0];
wire bne = ~Op[5]&~Op[4]&~Op[3]&Op[2]&~Op[1]&Op[0];
wire j = ~Op[5]&~Op[4]&~Op[3]&~Op[2]&Op[1]&~Op[0];
wire andi = ~Op[5]&~Op[4]&Op[3]&Op[2]&~Op[1]&~Op[0];
wire ori = ~Op[5]&~Op[4]&Op[3]&Op[2]&~Op[1]&Op[0];
wire addi = ~Op[5]&~Op[4]&Op[3]&~Op[2]&~Op[1]&~Op[0];
wire imm = andi|ori|addi; //immediate value type
//seperate control arrays for reference
wire [3:0] EX;
wire [2:0] M;
wire [1:0] WB;
// microcode control
assign regdst = r;
assign alusrc = lw|sw|imm;
assign memtoreg = lw;
assign regwrite = r|lw|imm;
assign memread = lw;
assign memwrite = sw;
assign branch = beq;
// EXE control
assign EX[3] = regdst;
assign EX[2] = alusrc;
assign EX[1] = r;
assign EX[0] = beq;
//M control
assign M[2] = branch;
assign M[1] = memread;
assign M[0] = memwrite;
//WB control
assign WB[1] = memtoreg; //not same as diagram
assign WB[0] = regwrite;
//output control
assign Out[8:7] = WB;
assign Out[6:4] = M;
assign Out[3:0] = EX;
endmodule