unit of the input geometry #3

Open
felixmusil opened this issue Jul 25, 2018 · 2 comments
Open

unit of the input geometry #3

felixmusil opened this issue Jul 25, 2018 · 2 comments

Comments

@felixmusil
Copy link

I ran nmr calculations with QE/GIPAW 6.1 and the same input geometries but with different units (one in angstrom and the other in bohr) and the resulting nmr shielding are different (see attached file).

What could be the reason for such discrepancy ?

CILWUP11.zip

@dceresoli
Copy link
Owner

I'm out of office for the next two weeks. I'm looking into it ASAP

@felixmusil
Copy link
Author

I ran the same comparison with the latest version of QE/GIPAW 6.1 and there are no problems there.

My collaborators and I ran many calculations with QE 6.1 svn rev. 13369 which seems to give problems with different units (see attached file in my previous post).
We also observe some discrepancies with the computed shifts between these two versions (mainly coming from the macroscopic shape contribution) so we are now trying to understand if we need to rerun all of these calculations.

Was there a bug corrected in GIPAW in between these two versions ?

CILWUP11_QE_version.zip

# for free to join this conversation on GitHub. Already have an account? # to comment