MSE Wall design - Matlab
Description:
> The script was written to primarily for design of MSE walls.
> The script calculates minimum length of geogrid required to resist loads from the pressure from
> (1) earth and (2) surcharge with groundwater (GW) level is low to not effect the MSE wall.
Assumption and Considerations:
(1) groundwater (GW) level is very low - does not effect the MSE wall stability.
(2) global stability is adequate.
(3) the surcharge load is uniform surcharge; no point load or line load
(4) geogrid is assumed to be extandable; hence, follows failure wedge defined by Rankine theory
for internal stability check.
(5) all the geogrid length and vertical spacing is kept constant for simplicity.
(6) pull-out resistance factor of geogrid is assumed to be 0.7*tan(effective friction angle of MSE fill)
(7) inclination of wall and backfill is vertical and horizontal, respectively.
(8) minimum width-to-height ratio (B/H) for MSE wall is 0.7