When you set the VR7x configuration in your VRCxxx it sets up the VR7x so it knows which inputs are VR10 or VR11 etc, and which relays control mixer valves:
ss ss ss ss ss ss
12 34 56 78 91 11
cfg 0 12
1: 01 01 00 00 00 00 01 02 00 03
2: 01 01 01 00 00 00 01 00 00 03
3: 01 01 00 00 00 20 22 00 00 00
6: 01 01 01 00 00 00 00 22 02 00
I am not sure about the first 4 bytes in the VR71 config - it looks like they should be mixer control, but config-3 has 3 mixer zones, and i guess the 4th byte is unused, as the "R13" connection in the VR71 seem to be not an output at all.
When you set the VR7x configuration in your VRCxxx it sets up the VR7x so it knows which inputs are VR10 or VR11 etc, and which relays control mixer valves:
VR70
Request: 10 52 b523 (9) Data: 00
sensor: 0=VR10,1=VR11,2=demand
relay: 1=mixer
VR71
Req: 10 26 b523 (11) Data: 04
sensor: 0=VR10,1=VR11,2=demand,3=PWM
I am not sure about the first 4 bytes in the VR71 config - it looks like they should be mixer control, but config-3 has 3 mixer zones, and i guess the 4th byte is unused, as the "R13" connection in the VR71 seem to be not an output at all.
this was using info from
https://professional.vaillant.co.uk/downloads/product-manuals/vrc-700/vrc-700-installation-instructions-1968307.pdf
page 33