+Apply a customized IdealAirSystem to Honeybee Rooms.
+-
+
+ Args:
+ _rooms: Honeybee Rooms to which the input ideal air properties will
+ be assigned.
+ _economizer_: Text to indicate the type of air-side economizer used on
+ the ideal air system. Economizers will mix in a greater amount of
+ outdoor air to cool the zone (rather than running the cooling system)
+ when the zone needs cooling and the outdoor air is cooler than the zone.
+ Choose from the options below. Default: DifferentialDryBulb.
+ * NoEconomizer
+ * DifferentialDryBulb
+ * DifferentialEnthalpy
+ dcv_: Boolean to note whether demand controlled ventilation should be
+ used on the system, which will vary the amount of ventilation air
+ according to the occupancy schedule of the zone. Default: False.
+ sensible_hr_: A number between 0 and 1 for the effectiveness of sensible
+ heat recovery within the system. Default: 0.
+ latent_hr_: A number between 0 and 1 for the effectiveness of latent heat
+ recovery within the system. Default: 0.
+ _heat_temp_: A number for the maximum heating supply air temperature
+ [C]. Default: 50, which is typical for many air-based HVAC systems.
+ _cool_temp_: A number for the minimum cooling supply air temperature
+ [C]. Default: 13, which is typical for many air-based HVAC systems.
+ _heat_limit_: A number for the maximum heating capacity in Watts. This
+ can also be the text 'autosize' to indicate that the capacity should
+ be determined during the EnergyPlus sizing calculation. This can also
+ be the text 'NoLimit' to indicate no upper limit to the heating
+ capacity. Default: 'autosize'.
+ _cool_limit_: A number for the maximum cooling capacity in Watts. This
+ can also be the text 'autosize' to indicate that the capacity should
+ be determined during the EnergyPlus sizing calculation. This can also
+ be the text 'NoLimit' to indicate no upper limit to the cooling
+ capacity. Default: 'autosize'.
+
+ Returns:
+ rooms: The input Rooms with their Ideal Air Systems edited.
+"""
+
+ghenv.Component.Name = "HB IdealAir"
+ghenv.Component.NickName = 'IdealAir'
+ghenv.Component.Message = '0.1.0'
+ghenv.Component.Category = 'Energy'
+ghenv.Component.SubCategory = '4 :: HVAC'
+ghenv.Component.AdditionalHelpFromDocStrings = '1'
+
+
+try: # import the honeybee-energy extension
+ from honeybee_energy.hvac.idealair import IdealAirSystem
+except ImportError as e:
+ raise ImportError('\nFailed to import honeybee_energy:\n\t{}'.format(e))
+
+try:
+ from ladybug_rhino.grasshopper import all_required_inputs
+except ImportError as e:
+ raise ImportError('\nFailed to import ladybug_rhino:\n\t{}'.format(e))
+
+
+if all_required_inputs(ghenv.Component):
+ # duplicate the initial objects
+ rooms = [room.duplicate() for room in _rooms]
+
+ for room in rooms:
+ if room.properties.energy.is_conditioned:
+ # check to be sure the assigned HVAC system is an IdealAirSystem
+ if not isinstance(room.properties.energy.hvac, IdealAirSystem):
+ room.properties.energy.add_default_ideal_air()
+
+ # create the customized ideal air system
+ new_ideal_air = room.properties.energy.hvac.duplicate()
+ if _economizer_ is not None:
+ new_ideal_air.economizer_type = _economizer_
+ if dcv_ is not None:
+ new_ideal_air.demand_controlled_ventilation = dcv_
+ if sensible_hr_ is not None:
+ new_ideal_air.sensible_heat_recovery = sensible_hr_
+ if latent_hr_ is not None:
+ new_ideal_air.latent_heat_recovery = latent_hr_
+ if _heat_temp_ is not None:
+ new_ideal_air.heating_air_temperature = _heat_temp_
+ if _cool_temp_ is not None:
+ new_ideal_air.cooling_air_temperature = _cool_temp_
+ if _heat_limit_ is not None:
+ new_ideal_air.heating_limit = _heat_limit_
+ if _cool_limit_ is not None:
+ new_ideal_air.cooling_limit = _cool_limit_
+
+ # assign the HVAC to the Room
+ room.properties.energy.hvac = new_ideal_air
diff --git a/honeybee_grasshopper_energy/user_objects/HB IdealAir.ghuser b/honeybee_grasshopper_energy/user_objects/HB IdealAir.ghuser
new file mode 100644
index 00000000..69e29cd4
Binary files /dev/null and b/honeybee_grasshopper_energy/user_objects/HB IdealAir.ghuser differ
diff --git a/samples/full_building_energy_model.gh b/samples/full_building_energy_model.gh
index b1ace3d0..3b7365b9 100644
Binary files a/samples/full_building_energy_model.gh and b/samples/full_building_energy_model.gh differ