mPower 3 Outlet subs wrong #9

Open
dersch81 opened this issue Dec 27, 2018 · 3 comments
Open

mPower 3 Outlet subs wrong #9

dersch81 opened this issue Dec 27, 2018 · 3 comments

Comments

@dersch81
Copy link

Hi, first of all it is working very easy! Thanks for your great work!

I have 2 devices mPower Mini and 3 Port Outlet.

With the Mini i have all subs as expected, voltage, power, energy everything is fine.

But with the 3 Port mPower i don't have any energy value it is always 0 for all ports.

@magcode
Copy link
Owner

magcode commented Dec 28, 2018

Hi,

can you check the output of

cat /proc/power/enabled1

In case it returns 0 please do the following:
echo 1 > /proc/power/enabled1

Then try again (plug in a device on port 1 and check in MQTT)

If that works now do the same for the other ports (enabled2 ... enabled3)

@dersch81
Copy link
Author

Yes that was the case. Now i get the energy value via MQTT. Thanks

@magcode
Copy link
Owner

magcode commented Dec 31, 2018

Thanks for feedback. I'll either add this to the documentation or maybe add some scripting to enable it automatically.