Maximum cell voltage #12

Open
kaklik opened this issue Oct 3, 2024 · 1 comment
Open

Maximum cell voltage #12

kaklik opened this issue Oct 3, 2024 · 1 comment

Comments

@kaklik
Copy link
Contributor

kaklik commented Oct 3, 2024

delic v solarmini je 100:110 k ohm
dava to 2,69 V az 2,77 V naprazdno pri 1 % odporech
R7 = 110 k
R8 = 100 k

Originally posted by @kakl in #1 (comment)

@kaklik
Copy link
Contributor Author

kaklik commented Oct 3, 2024

Podle mých dosavadních experimentů na dvou kusech SOLARMINIBAT je tohle nastavení zřejmě neoptimální. Protože v zřejmě důsledku tolerance VCRTL (1.2 až 1.3V) je na článku pozorovatelné i nízké napětí pod 2.5 V.