Temperature correction missing for some sensors #1044

Open
steefan85 opened this issue Nov 4, 2024 · 0 comments
Open

Temperature correction missing for some sensors #1044

steefan85 opened this issue Nov 4, 2024 · 0 comments

Comments

@steefan85
Copy link

There is a feature for temperature correction in the settings which I used for my BME280 to lower the temperaure value.
Recently I changed to a SHT3X Sensor and the correction is now ineffective.

I reviewed the code and saw that for BME280 there is a correction

else
{
last_value_BMX280_T = t + readCorrectionOffset(cfg::temp_correction);
last_value_BMX280_P = p;
if (bmx280.sensorID() == BME280_SENSOR_ID)

but for some sensors the correction is missing, e.g.:

else
{
last_value_SHT3X_T = t;
last_value_SHT3X_H = h;

The SHT31x is not the only affected sensor.