BME 280 liefert nur noch 100% Luftfeuchte #544

Closed
dora71 opened this issue Nov 9, 2019 · 10 comments
Closed

BME 280 liefert nur noch 100% Luftfeuchte #544

dora71 opened this issue Nov 9, 2019 · 10 comments

Comments

@dora71
Copy link

dora71 commented Nov 9, 2019

Seit dem Firmware Update auf Version NRZ-2019-125-B1 liefert mein BME 280 nur noch 100% Luftfeuchte.

Temperatur und Luftdruck sind ok.
Ein Upgrade auf die Beta Software NRZ-2019-126-B5 brachte keine Verbesserung.

An der Verkabelung wurde nichts geändert.

@BudBundi
Copy link

BudBundi commented Nov 9, 2019

Ich dachte es auch lange bei mir, aber ich habe auch einige Werte über 90% dabei. Allgemein scheint dort vielleicht irgendeine Umrechnung nicht zu passen.

@dirkmueller
Copy link
Collaborator

Bildschirmfoto 2019-11-09 um 22 25 49

@dirkmueller
Copy link
Collaborator

dirkmueller commented Nov 9, 2019

so in general a value of near 100% is not unusual at this time of the year. a constant value of 100% might indicate some problem however.

@sanitariu
Copy link

I have the same. I think it is a bug in the firmware. Developers must return some version back so all stations download/update automatically. Sensors SDS011 and BME 280 seems do not work well with the latest firmware.

@dirkmueller
Copy link
Collaborator

@sanitariu are you having the issue described here which is 100% humidity always or something else?

@sanitariu
Copy link

I have humidity now 31.4 % and it is raining. Also temperature is +2 degree but sensors shows 23.2 °C.
I would like a way to return to older version like some from 2018 without going to the roof and dismount everything. How i can do it ? Also other sensor for dust does not show correct values. This started from some days after latest update.
But yes it do not show 100%

@dirkmueller
Copy link
Collaborator

@sanitariu ok, so it is a different issue. please create a new one, it is free :-) I'm trying to help you there. Regarding the question, there is no builtin downgrade support for OTA. we assume that newer is better. please try the BETA version (check both the "use update" as well as "use beta" flag in configuration and save). I believe the issue is fixed already.

@dirkmueller
Copy link
Collaborator

I can not reproduce this with my set of BME280 sensors. Any user with this issue please share details.

@ricki-z
Copy link
Member

ricki-z commented Nov 27, 2019

And if possible please send me a picture of the module to rajko (at) sensor.community.

@dirkmueller
Copy link
Collaborator

please reopen when information can be provided.