Possible memory leak when manually aborting an association #912

Open
pchristos opened this issue Jan 30, 2024 · 7 comments
Open

Possible memory leak when manually aborting an association #912

pchristos opened this issue Jan 30, 2024 · 7 comments
Labels
Milestone

Comments

@pchristos
Copy link

pchristos commented Jan 30, 2024

Hi,

I have investigated a memory leak, which seems to be related to attempts of manually aborting associations.

Minimal example:

def _on_pdu_recv(self, event):
    # Method bound to `EVT_PDU_RECV` event.
    if isinstance(event.pdu, A_RELEASE_RQ):
        self._on_handle_a_release_rq(event)

def _on_handle_a_release_rq(self, event):
    try:
        do_something_with_event(event)
    except Exception:
        # The following line of code kills the Association thread. The DUL's 
        # FSM is stuck in `Sta6`, thus it is not killed by the Association 
        # thread's `kill()` method, which is invoked by the calling to `abort()` 
        # below. As a result, the `kill()` method is stuck in a `while` loop
        # trying to stop the DUL.
        event.assoc.abort()
        # Due to the above, the line below is never executed.
        do_something_else()

The above seems like a straight-forward way of aborting, but leads to leaking of DUL threads.

I have found that the below alternative works better:

def _on_pdu_recv(self, event):
    # Method bound to `EVT_PDU_RECV` event.
    if isinstance(event.pdu, A_RELEASE_RQ):
        self._on_handle_a_release_rq(event)

def _on_handle_a_release_rq(self, event):
    try:
        do_something_with_event(event)
    except Exception:
        # Manually create the PDU to abort.
        abort_pdu = A_ABORT_RQ()
        abort_pdu.source = 0x02
        abort_pdu.reason_diagnostic = 0x00
        event.assoc.dul.socket.send(abort_pdu.encode())
        event.assoc.dul.assoc.is_aborted = True
        event.assoc.dul.assoc.is_established = False
        # Hard shutdown of the Association and DUL reactors.
        event.assoc.dul.assoc._kill = True
        event.assoc.dul._kill_thread = True
        # The line below is called.
        do_something_else()

The above approach is based on this.

I am wondering what is actually the best approach to abort an association at any time. Thoughts?

Originally posted by @pchristos in #652 (comment)

pydicom 2.3.1
pynetdicom 2.0.2

@scaramallion scaramallion added this to the v2.1.0 milestone Jan 30, 2024
@scaramallion
Copy link
Member

Yeah, there's some iffy behaviour in shutting the DUL down properly that will be fixed in the next release.

@pchristos
Copy link
Author

Thanks! ETA for the next release?

@scaramallion
Copy link
Member

It'll be quite a while, I think. I've been focussing on pydicom's v3.0 release.

@pchristos
Copy link
Author

In that case, what's your recommended approach? Is the proposed alternative a valid approach for now?

@scaramallion scaramallion modified the milestones: v2.1.0, v2.2.0 May 30, 2024
@pchristos
Copy link
Author

Hey, any updates on this?

@scaramallion
Copy link
Member

Nothing so far, but probably soonish.

@pchristos
Copy link
Author

Any updates?