Skip to content

[HELP] <title> Does not read data from the inverter axioma energy ismppt bf 3000 #185

New issue

Have a question about this project? # for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “#”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? # to your account

Closed
Dior34 opened this issue Dec 1, 2024 · 6 comments
Labels
help wanted Extra attention is needed

Comments

@Dior34
Copy link

Dior34 commented Dec 1, 2024

A clear and concise description of what the problem is.

Does not read data from the inverter axioma energy ismppt bf 3000.
Several times it was possible to get data in the Home Assistant, this confirms that the settings are correct. In this case, the Solar2MQTT_d1_mini_1.2.0-Pre4.bin firmware was used. The data was obtained 3 times for 2-3 hours. The rest of the time, either does not read anything at all or 0
Firmware changes do not help.
at the same time, wachpower receives data only if the version is older than version 1.1.9. i.e. 1.1.10 does not receive
Connecting with one wire to the TTL board and to the computer

Additional context

HA
camphoto_959030623
SharedScreenshot
wachpower
Знімок екрана 2024-12-02 182404

@Dior34 Dior34 added the help wanted Extra attention is needed label Dec 1, 2024
@softwarecrash
Copy link
Owner

What tells the webserial (or USB serial) from the ESP when No Data is recived?

@Dior34
Copy link
Author

Dior34 commented Dec 2, 2024

I used different boards based on 8266mod. also differences in TTL boards from different manufacturers
photo_2024-12-02_09-59-19
photo_2024-12-02_09-59-17
photo_2024-12-02_09-59-15
photo_2024-12-02_09-59-13
photo_2024-12-02_09-59-05
photo_2024-12-02_10-03-17
photo_2024-12-02_10-23-00

There is a photo of a successful connection left
photo_2024-12-02_10-04-52

If the connection is successful, the PI30 inverter protocol is determined
There are still photos of various unsuccessful connections .

connected with connectors, then switched to soldering. (Immediately after soldering there was the first success)
tried under different names

Web Console v 2.2.0 pre.6

[WebSerial] Connecting...
[WebSerial] Connected...
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
----------------- End Autodetect -----------------
ProzessData P:0 C:0
WS data send
MQTT Client State: 0
Data sent to MQTT
[C: QPI][CR: 0][CC: 0][L: 3]
QPI: NOA (Length: 3)
[C: ^P005PI][CR: 0][CC: 0][L: 3]
^P005PI: NOA (Length: 3)
Try Autodetect Protocol
[C: QPI][CR: 0][CC: 0][L: 3]
QPI: NOA (Length: 3)
[C: ^P005PI][CR: 0][CC: 0][L: 3]
^P005PI: NOA (Length: 3)
Try Autodetect Protocol
[C: QPI][CR: 0][CC: 0][L: 3]
QPI: NOA (Length: 3)
[C: ^P005PI][CR: 0][CC: 0][L: 3]
^P005PI: NOA (Length: 3)
Try Autodetect Modbus device
Init MUST PV/PH 18 protocol, baud 19200, modbusAddr 4
Response Timed Out
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
Init DEYE protocol, baud 9600, modbusAddr 1
Response Timed Out
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
Init Anenji protocol, baud 9600, modbusAddr 1
Response Timed Out
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
Response Timed Out
Response Timed Out
Time-out
Request failed!
----------------- End Autodetect ----------------

Web Console v 1.2.0 pre.4

[18:08:24] ----------------- End Autodetect -----------------

[18:08:24] MQTT Client State: 0

[18:08:24] ----------------- Start Autodetect -----------------

[18:08:26] [C: QPI][CR: 0][CC: 0][L: 3]

[18:08:26]

[18:08:26] QPI: NAK (Length: 3)

[18:08:26]

[18:08:28] [C: ^P005PI][CR: 0][CC: 0][L: 3]

[18:08:28]

[18:08:28] ^P005PI: NAK (Length: 3)

[18:08:28]

[18:08:28] Try Autodetect Protocol

[18:08:28]

[18:08:30] [C: QPI][CR: 0][CC: 0][L: 3]

[18:08:30]

[18:08:30] QPI: NAK (Length: 3)

[18:08:30]

[18:08:32] [C: ^P005PI][CR: 0][CC: 0][L: 3]

[18:08:32]

[18:08:32] ^P005PI: NAK (Length: 3)

[18:08:32]

[18:08:32] Try Autodetect Protocol

[18:08:32]

[18:08:34] [C: QPI][CR: 0][CC: 0][L: 3]

[18:08:34]

[18:08:34] QPI: NAK (Length: 3)

[18:08:34]

[18:08:36] [C: ^P005PI][CR: 0][CC: 0][L: 3]

[18:08:36]

[18:08:36] ^P005PI: NAK (Length: 3)

[18:08:36]

[18:08:37] Try Autodetect Modbus device

[18:08:37]

[18:08:38] Response Timed Out

[18:08:38]

[18:08:40] Response Timed Out

[18:08:40]

[18:08:40] Time-out

[18:08:40]

[18:08:40] Request failed!

[18:08:41]

[18:08:42] Response Timed Out

[18:08:42]

[18:08:44] Response Timed Out

[18:08:44]

[18:08:44] Time-out

[18:08:44]

[18:08:45] Request failed!

[18:08:45]

[18:08:46] Response Timed Out

[18:08:46]

[18:08:48] Response Timed Out

[18:08:48]

[18:08:48] Time-out

[18:08:49]

[18:08:49] Request failed!

[18:08:49]

[18:08:50] Response Timed Out

[18:08:51]

[18:08:52] Response Timed Out

[18:08:52]

[18:08:53] Time-out

[18:08:53]

[18:08:53] Request failed!

[18:08:53]

[18:08:53] ----------------- End Autodetect -----------------

POWER SUPPLY of boards from USB from a separate power supply unit or computer

@softwarecrash
Copy link
Owner

I have No Idea why it Work and dont Work later.
Looks Like a communication issue

@Dior34
Copy link
Author

Dior34 commented Dec 4, 2024 via email

@softwarecrash
Copy link
Owner

you can try to force a protocol by paste following in the webserial console

setp x
1= PI18,
2= PI30,
3= MODBUS_MUST,
4= MODBUS_DEYE,
5= MODBUS_ANENJI,
6= PROTOCOL_TYPE_MAX

@Dior34
Copy link
Author

Dior34 commented Dec 7, 2024

Still managed to start.
Ordered a new (third) TTL board. And everything worked.
Can you add this model of hybrid inverter as working

Thanks!

# for free to join this conversation on GitHub. Already have an account? # to comment
Labels
help wanted Extra attention is needed
Projects
None yet
Development

No branches or pull requests

2 participants