Skip to content
New issue

Have a question about this project? # for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “#”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? # to your account

proto: can't skip unknown wire type 7 #373

Open
martea opened this issue Apr 22, 2021 · 2 comments
Open

proto: can't skip unknown wire type 7 #373

martea opened this issue Apr 22, 2021 · 2 comments

Comments

@martea
Copy link

martea commented Apr 22, 2021

trying to use hercules combine in windows, to combine hercules results from the --burndown but ending up with same error.

image

@znerd
Copy link

znerd commented Apr 9, 2022

@martea : It could be helpful if you provide a reproducible case that others could also execute.

@helllamer
Copy link

This occurs because of using hercules -m burndown-proxy ... > file.pb without --pb flag on previous steps.

Without --pb flag, hercules generates text representation, that cannot be parsed by hercules combine file1 file2 ... -- combile will fail with such parse error.

# for free to join this conversation on GitHub. Already have an account? # to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

3 participants