Skip to content
New issue

Have a question about this project? # for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “#”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? # to your account

Abort and connect flags used uninitialized #1379

Closed
abaskin opened this issue Mar 28, 2022 · 0 comments
Closed

Abort and connect flags used uninitialized #1379

abaskin opened this issue Mar 28, 2022 · 0 comments
Labels
bug Validated BUG

Comments

@abaskin
Copy link

abaskin commented Mar 28, 2022

Basic Infos

Hardware

WiFimanager Branch/Release: Master

Esp8266/Esp32: ESP8266

Hardware: NodeMCU

Core Version: 2.4.0

Description

On object creation the abort and connect flags are not initialized. They are initialized by startConfigPortal() but not by startWebPortal(). As a result when startWebPortal() is called (an on demand portal for example), process() will fail with a "process loop abort" error if the abort flag happens to contain a non-zero value.

@tablatronix tablatronix added the bug Validated BUG label Mar 28, 2022
# for free to join this conversation on GitHub. Already have an account? # to comment
Labels
bug Validated BUG
Projects
None yet
Development

No branches or pull requests

2 participants