1 | Vendor | System / Component | Default Port | Metasploit |
---|---|---|---|---|
2 | Advantech WebAccess | Advantech WebAccess SQL Injection | 80 | auxiliary/admin/scada/advantech_webaccess_dbvisitor_sqli |
3 | General Electric | GE Proficy Cimplicity WebView substitute.bcl Directory Traversal | 80 | auxiliary/admin/scada/ge_proficy_substitute_traversal |
4 | Schneider | Schneider Modicon Remote START/STOP Command | 502 | auxiliary/admin/scada/modicon_command |
5 | Schneider | Schneider Modicon Quantum Password Recovery | 21 | auxiliary/admin/scada/modicon_password_recovery |
6 | Schneider | Schneider Modicon Ladder Logic Upload/Download | 502 | auxiliary/admin/scada/modicon_stux_transfer |
7 | Allen-Bradley/Rockwell | Allen-Bradley/Rockwell Automation EtherNet/IP CIP Commands | 44818 | auxiliary/admin/scada/multi_cip_command |
8 | PhoenixContact PLC | PhoenixContact PLC Remote START/STOP Command | 1962 | auxiliary/admin/scada/phoenix_command |
9 | Beckhoff | TwinCat | 48899 | auxiliary/dos/scada/beckhoff_twincat |
10 | General Electric | D20 PLC | 2 | auxiliary/gather/d20pass |
11 | General Electric | D20 PLC | 69 | auxiliary/dos/scada/d20_tftp_overflow |
12 | 7-Technologies | 7-Technologies IGSS 9 IGSSdataServer.exe DoS | 12401 | auxiliary/dos/scada/igss9_dataserver |
13 | Digi ADDP | Digi ADDP Remote Reboot Initiator | 2362 | auxiliary/scanner/scada/digi_addp_reboot |
14 | Digi ADDP | Digi ADDP Information Discovery | 2362 | auxiliary/scanner/scada/digi_addp_version |
15 | Digi International | Advance device Discovery Protocol | 771 | auxiliary/scanner/scada/digi_realport_serialport_scan |
16 | Digi International | Advance device Discovery Protocol | 771 | auxiliary/scanner/scada/digi_realport_version |
17 | Indusoft | InduSoft Web Studio Arbitrary Upload Remote Code Execution | 4322 | exploit/windows/scada/indusoft_webstudio_exec |
18 | Indusoft | Indusoft WebStudio NTWebServer Remote File Access | 80 | auxiliary/scanner/scada/indusoft_ntwebserver_fileaccess |
19 | Digital Bond | Koyo DirectLogic PLC Password Brute Force Utility | 28784 | auxiliary/scanner/scada/koyo_login |
20 | EsMnemon | Modbus Client Utility | 502 | auxiliary/scanner/scada/modbus_findunitid |
21 | EsMnemon and Arnaud Soullie | Modbus Client Utility | 502 | auxiliary/scanner/scada/modbusclient |
22 | EsMnemon | Modbus Client Utility | 502 | auxiliary/scanner/scada/modbusdetect |
23 | Siemens Profinet | Siemens Profinet Scanner | auxiliary/scanner/scada/profinet_siemens | |
24 | Sielco Sistemi | Winlog Remote File Access | 46824 | auxiliary/scanner/scada/sielco_winlog_fileaccess |
25 | KeyHelp | KeyHelp ActiveX LaunchTriPane Remote Code Execution Vulnerability | 80 | exploit/windows/browser/keyhelp_launchtripane_exec |
26 | TeeChart Professional | TeeChart Professional ActiveX Control Trusted Integer Dereference | 8080 | exploit/windows/browser/teechart_pro |
27 | KingScada | KingScada kxClientDownload.ocx ActiveX Remote Code Execution | 8080 | exploit/windows/browser/wellintech_kingscada_kxclientdownload |
28 | BACnet | OPC Client | exploit/windows/fileformat/bacnet_csv | |
29 | ScadaTec | ModbusTag Server ScadaPhone | exploit/windows/fileformat/scadaphone_zip | |
30 | ABB MicroSCADA | ABB MicroSCADA wserver.exe Remote Code Execution | 12221 | exploit/windows/scada/abb_wserver_exec |
31 | Schneider Electric | CitectSCADA | 20222 | exploit/windows/scada/citect_scada_odbc |
32 | 3S | SCADA 3S CoDeSys Gateway Server Directory Traversal | 1211 | exploit/windows/scada/codesys_gateway_server_traversal |
33 | 3S | SCADA 3S CoDeSys CmpWebServer Stack Buffer Overflow | 8080 | exploit/windows/scada/codesys_web_server |
34 | AzeoTech | DAQ Factory | 20034 | exploit/windows/scada/daq_factory_bof |
35 | Siemens Technomati | Siemens FactoryLink 8 CSService Logging Path Param Buffer Overflow | 7580 | exploit/windows/scada/factorylink_csservice |
36 | Siemens Technomati | Siemens FactoryLink vrn.exe Opcode 9 Buffer Overflow | 7579 | exploit/windows/scada/factorylink_vrn_09 |
37 | General Electric | GE Proficy CIMPLICITY gefebt.exe Remote Code Execution | 80 | exploit/windows/scada/ge_proficy_cimplicity_gefebt |
38 | Iconics | Iconics GENESIS32 Integer Overflow Version 9.21.201.01 | 38080 | exploit/windows/scada/iconics_genbroker |
39 | Iconics | ICONICS WebHMI ActiveX Buffer Overflow | exploit/windows/scada/iconics_webhmi_setactivexguid | |
40 | 7-Technologies | IGSS | 12401 | exploit/windows/scada/igss9_igssdataserver_listall |
41 | 7-Technologies | IGSS | 12401 | exploit/windows/scada/igss9_igssdataserver_rename |
42 | 7-Technologies | IGSS | exploit/windows/scada/igss9_misc | |
43 | 7-Technologies | IGSS | 12397 | exploit/windows/scada/igss_exec_17 |
44 | MOXA | MOXA Device Manager Tool 2.1 Buffer Overflow | exploit/windows/scada/moxa_mdmtool | |
45 | Procyon | Procyon Core Server HMI Coreservice.exe Stack Buffer Overflow | 23 | exploit/windows/scada/procyon_core_server |
46 | DATAC RealWin | DATAC RealWin SCADA Server Buffer Overflow | 910 | exploit/windows/scada/realwin |
47 | DATAC RealWin | DATAC RealWin SCADA Server 2 On_FC_CONNECT_FCS_a_FILE Buffer Overflow | 910 | exploit/windows/scada/realwin_on_fc_binfile_a |
48 | DATAC RealWin | RealWin SCADA Server DATAC Login Buffer Overflow | 910 | exploit/windows/scada/realwin_on_fcs_login |
49 | DATAC RealWin | DATAC RealWin SCADA Server SCPC_INITIALIZE Buffer Overflow | 912 | exploit/windows/scada/realwin_scpc_initialize |
50 | DATAC RealWin | DATAC RealWin SCADA Server SCPC_INITIALIZE_RF Buffer Overflow | 912 | exploit/windows/scada/realwin_scpc_initialize_rf |
51 | DATAC RealWin | DATAC RealWin SCADA Server SCPC_TXTEVENT Buffer Overflow | 912 | exploit/windows/scada/realwin_scpc_txtevent |
52 | Measuresoft ScadaPro | Measuresoft ScadaPro Remote Command Execution | 11234 | exploit/windows/scada/scadapro_cmdexe |
53 | Sunway Forcecontrol | Sunway Forcecontrol SNMP NetDBServer.exe Opcode 0x57 | 2001 | exploit/windows/scada/sunway_force_control_netdbsrv |
54 | Sielco Sistemi | Sielco Sistemi Winlog Buffer Overflow | 46823 | exploit/windows/scada/winlog_runtime |
55 | Sielco Sistemi | Sielco Sistemi Winlog Buffer Overflow 2.07.14 - 2.07.16 | 46824 | exploit/windows/scada/winlog_runtime_2 |
56 | Yokogawa | Yokogawa CENTUM CS 3000 BKBCopyD.exe Buffer Overflow | 20111 | exploit/windows/scada/yokogawa_bkbcopyd_bof |
57 | Yokogawa | Yokogawa CS3000 BKESimmgr.exe Buffer Overflow | 34205 | exploit/windows/scada/yokogawa_bkesimmgr_bof |
58 | Yokogawa | Yokogawa CS3000 BKFSim_vhfd.exe Buffer Overflow | 20010 | exploit/windows/scada/yokogawa_bkfsim_vhfd |
59 | Yokogawa | Yokogawa CENTUM CS 3000 BKHOdeq.exe Buffer Overflow | 20171 | exploit/windows/scada/yokogawa_bkhodeq_bof |
60 | Yokogawa | Yokogawa CENTUM CS 3000 BKCLogSvr.exe Heap Buffer Overflow | 52302 | auxiliary/dos/scada/yokogawa_logsvr |
61 | Yokogawa | Yokogawa BKBCopyD.exe Client | 20111 | auxiliary/admin/scada/yokogawa_bkbcopyd_client |