Read ZSOIL8 from HYDRO_nlist if sys_cpl ne 1 #578

Draft
wants to merge 1 commit into
base: v5.2.x
Choose a base branch
from

Conversation

danrosen25
Copy link
Collaborator

TYPE: bug fix

KEYWORDS: ZSOIL8, HYDRO_nlist, config

SOURCE: @danrosen25 NCAR

DESCRIPTION OF CHANGES: This fixes an issue where the user cannot specify the soil depths (a.k.a. soil layer thickness) in configuration files during coupled runs. If the sys_cpl type does not equal 1 the initialization routine will read ZSOIL8 from the HYDRO_nlist namelist in the hydro.namelist file. This may is not fully backwards compatible because previous coupling applications may have relied on hardcoded soil depths.

ISSUE: #571

TESTS CONDUCTED: I tested using sys_cpl=2 in a coupled LIS-WRFHYDRO application using NUOPC infrastructure.

Checklist

  • Closes issue NSOIL8 not read properly when running sys_cpl != 1 #571
  • Tests added (unit tests and/or regression/integration tests)
  • Backwards compatible
  • Requires new files? If so, how to generate them.
  • Documentation included
  • Short description in the Development section of NEWS.md

@rcabell rcabell mentioned this pull request Feb 1, 2022