This dataset consists of brain scans of a single human phantom acquired on multiple MRI devices across North America over a period of 11 years. In addition to the human brain images, lego phantom scans have been acquired in parallel for quality assessments over time across sites.
MRI modalities include: T1-weighted (t1w), T2-weighted (t2w), resting state BOLD (bold), 25-direction DWI (dwi25), 65-direction DWI (dwi65) as well as fieldmaps for the BOLD and DWI acquisitions (fieldmapBOLD and fieldmapDWI).
The human phantom data were collected once a year during two MRI sessions. Those two sessions were either performed the same day or with a few days apart.
Data are organized by subject_ID/Visit_Label
.
.
|__ subject-1
|__ visit-label-1
|__ images
|__ images.json
|__ phantom_<subject-1>_<visit-label-1>_<scan-type>_<run-number>.mnc
|__ phantom_<subject-1>_<visit-label-1>_<scan-type>_<run-number>.mnc
...
|__ visit_label_2
...
|__ subject_2
|__ subject_3
...
|__ DATS.json
|__ README.md
The ID of the human phantom subject is 963271
and the 9 other subjects present in the dataset are lego phantoms.
Visit labels for the human phantom acquisitions are labelled according to the convention <SiteAbbreviation>_<ScanSessionNumber>_<AcquisitionDate>
Example: MNI_SCAN1_20101125
corresponds to scan session number 1 at the MNI site performed on November 25th, 2010.
The visit labels of the lego phantom acquisitions are labelled according to the convention
<SiteAbbreviation>_<AcquisitionDate>
All images are available in MINC format.
All MRI scanners were manufacured by SIEMENS.
Abbreviation | Name | Scanner Model | Scanner software Versions |
---|---|---|---|
MNI | Montreal Neurological Institute | TrioTim | Syngo MRI B15 & B17 |
PH1 | Philadelphia Children's Hospital MR1 | TrioTim | Syngo MRI B15 & B17 |
PH5 | Philadelphia Children's Hospital MR5 | TrioTim | Syngo MRI B17 |
SEA | Seattle Children Hospital | TrioTim | Syngo MRI B15 & B17 |
SLC | St Louis CIR | TrioTim | Syngo MRI B17 |
SLH | St Louis Children's Hospital | TrioTim | Syngo MRI B15 & B17 |
SLR | St Louis Washington University | TrioTim | Syngo MRI B15 & B17 |
UMP | University of Minnesota Prisma Scanner | Prisma fit | Syngo MR D13D |
UMT | University of Minnesota Tim Trio Scanner | TrioTim | Syngo MR B17 |
UNH | University of North Carolina Hospital | TrioTim | Syngo MRI B15, B17 & B19 |
UNR | University of North Carolina Research. | TrioTim | Syngo MR B17 & B19 |
The IBIS Network (https://www.ibis-network.org/) and the NIH (https://www.nih.gov/).