Kia64: Add sanity checking for last cellvoltages #745
Merged
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
What
This PR implements a sanity check on the last cellvoltages for Kia64/40kWh packs
Why
Some 90S packs incorrectly report some garbage on the unpopulated cells. Attached is a screenshot from a Kia 40kWh 375A0 - K4403

How
We check the cells above 85. If the value seems sus, we zero it