##Procedure

  1. prepare the sensor
  2. setting the focus
  3. collect calibration data
    1. in-/extrinsics calibration (static calibration)
    2. imu-camera calibration (dynamic calibration)
  4. run the calibration
    1. in-/extrinsic camera calibration
    2. camera-IMU calibration
  5. collect results

##Requirements

  • ROS sensor driver is running (image/imu data)
  • good Aprilgrid target (yaml / pdf)
  • Siemens star (or similar camera focus test pattern)
  • IMU configuration for ADIS16448 (yaml)

##1) Sensor preparation

  1. make sure the sensor publishes all image and imu streams to ROS

  2. minimize the motion blur with a good light source and by reducing the shutter times: Shutter times can be set using the following commands:

    rosrun dynamic_reconfigure dynparam set /slam_sensor "{'cam0_agc_enable': 0, 'cam0_aec_enable': 0, 'cam0_coarse_shutter_width': 300}"
    rosrun dynamic_reconfigure dynparam set /slam_sensor "{'cam1_agc_enable': 0, 'cam1_aec_enable': 0, 'cam1_coarse_shutter_width': 300}"

    Observe the result on an image window and tweak the shutter until you get a good image:

    rosrun image_view image_view image:=/cam0/image_raw &
    rosrun image_view image_view image:=/cam1/image_raw &

##2) Setting the focus

  1. point the cameras on a Siemens star (or similar pattern)

  2. start the focus tool

    kalibr_camera_focus --topic /cam0/image_raw /cam1/image_raw

  3. set the focus of both cameras by:

    1. reducing the interference visible around the center of the Siemens star
    2. minimizing the focus measure provided by the tool

Make sure a Teflon band or thread-locking glue prevents unintentional focus changes after this step.

##2) Collect calibration data In this step we need to collect two calibration datasets with the following properties:

  1. static dataset (in-/extrinsic calibration of the cameras)

    • attach the sensor somewhere and move the target
    • limit the camera streams to ~4 Hz
    • make sure to cover the entire field of view of the camera
    • use skewed views and varying distances to the calibration target

    view images with:

    rosrun image_view image_view image:=/cam0/image_raw &
    rosrun image_view image_view image:=/cam1/image_raw &

    record bag with:

    rosbag record /cam0/image_raw /cam1/image_raw -O static.bag

  2. dynamic dataset (spatial camera-imu calibration)

    • move the sensor (target is fixed)
    • cameras should run at 20 Hz and IMU at 200 Hz
    • try to excite all rotation and acceleration axis of the IMU
    • avoid shocks
    • good illumination and shutter times are crucial here (to avoid motion blur while exciting the IMU)

    view images with:

    rosrun image_view image_view image:=/cam0/image_raw &
    rosrun image_view image_view image:=/cam1/image_raw &

    record bag with:

    rosbag record /cam0/image_raw /cam1/image_raw /imu0 -O dynamic.bag

##3) Run the calibration

  1. calibration of camera in/extrinsics

    1. run calibration

    kalibr_calibrate_cameras --models pinhole-equi pinhole-equi --topics /cam0/image_raw /cam1/image_raw --bag static.bag --target aprilgrid_6x6.yaml

    1. inspect the result plots
    2. verify calibration on the live image stream

    kalibr_camera_validator --chain chain.yaml --target aprilgrid_6x6.yaml

  2. camera-imu calibration

    1. run calibration

    kalibr_calibrate_imu_camera --cam chain.yaml --target aprilgrid_6x6.yaml --imu imu0.yaml --bag dynamic.bag

    1. inspect the result plots
      • make sure the predicted accelerations & angular velocities fit the IMU measurements
      • reprojection errors should be in a normal range

##4) Collect results Both calibrators have written reports to the working directory containing the plots shown during the calibration. Further a chain.yaml has been written by the camera calibrator and is extended by the imu-camera calibrator with its results to the file chain_cimu.yaml. Please refer to this page for more detail about the formats.