Stitching issue from master pattern equator with get_patterns() #357
Comments
I have seen something like this and it was related to fact that
hemisphere size in pixels was even number while should be odd.
But it was not EMsoft simulation but Dynamics.
Grzegorz
W dniu 2021-05-19 17:34, Håkon Wiik Ånes napisał(a):
… When sampling a hexagonal master pattern of a phase with point group
6mm, I get a stitching line where the "seam" between the two
hemispheres is:
[1]
The detector normal is parallel to the sample normal (sample_tilt=0),
and the crystal orientation is (30, 0, 0) degrees. The seam can be
seen between the [1000] and [1100] zone axes.
The master pattern's northern and southern hemispheres in
stereographic projection, generated with EMsoft v5.0:
[2]
Don't know the reason for this issue, and don't have the time to look
into it at the moment. Reported it here so we can deal with this at a
later time.
--
You are receiving this because you are subscribed to this thread.
Reply to this email directly, view it on GitHub [3], or unsubscribe
[4].
Links:
------
[1]
https://user-images.githubusercontent.com/12139781/118839435-c3074100-b8c6-11eb-938b-23d5c88b34bc.png
[2]
https://user-images.githubusercontent.com/12139781/118840047-53de1c80-b8c7-11eb-9181-0270dbc9abb6.png
[3] #357
[4]
https://github.com/notifications/unsubscribe-auth/AI3HGBQJW4KAQMUPYG3QWILTOPK73ANCNFSM45E54DDA
--
Cios Grzegorz
Academic Centre for Materials and Nanotechnology (ACMiN)
AGH University of Science and Technology, Krakow, Poland
30 Mickiewicza, 30-059 Krakow
bldg. D-16 (Kawiory 30, 30-055 Krakow), room 2.23
tel: +48 12 617 52 78
|
Thanks for letting me know, @CiosG! Just so I understand you correctly, you saw this after sampling with another software than kikuchipy ( I think the reason that I haven't seen this before is that I've mostly worked with centrosymmetric materials where we only need the northern hemisphere of the master pattern. So I think all sampling from non-centrosymmetric master patterns where we need both hemispheres have this issue... The same pattern simulated with EMsoft with the exact same conditions: |
The master patterns above had 1001 x 1001 pixels. |
After simulation with DynamicS we need to save the master pattern
(stereographic projection) in odd number dimensions like 513x513 and
then we stitch
two the same hemispheres. When I once did 512x512 I have seen similar
stitches.
I think EMSoft does something similar to keep the number odd.
In the EMEBSDmaster.nml:
! number of pixels along x-direction of the square master pattern
(2*npx+1 = total number)
npx = 500,
best regards
Grzegorz
W dniu 2021-05-19 18:10, Håkon Wiik Ånes napisał(a):
… Thanks for letting me know, @CiosG [1]! Just so I understand you
correctly, you saw this after sampling with another software than
kikuchipy (MasterPattern.get_patterns()). Sampling with Bruker
DynamicS?
I think the reason that I haven't seen this before is that I've mostly
worked with centrosymmetric materials where we only need the northern
hemisphere of the master pattern. So I think all sampling from
non-centrosymmetric master patterns where we need both hemispheres
have this issue...
The same pattern simulated with EMsoft with the exact same conditions:
[2]
--
You are receiving this because you were mentioned.
Reply to this email directly, view it on GitHub [3], or unsubscribe
[4].
Links:
------
[1] https://github.com/CiosG
[2]
https://user-images.githubusercontent.com/12139781/118846831-652a2780-b8cd-11eb-87f9-cfcf9058ae92.png
[3]
#357 (comment)
[4]
https://github.com/notifications/unsubscribe-auth/AI3HGBX7OYZI5BLTRAFSD3TTOPPIVANCNFSM45E54DDA
--
Cios Grzegorz
Academic Centre for Materials and Nanotechnology (ACMiN)
AGH University of Science and Technology, Krakow, Poland
30 Mickiewicza, 30-059 Krakow
bldg. D-16 (Kawiory 30, 30-055 Krakow), room 2.23
tel: +48 12 617 52 78
|
When sampling a hexagonal master pattern of a phase with point group 6mm, I get a stitching line where the "seam" between the two hemispheres is:
The detector normal is parallel to the sample normal (
sample_tilt=0
), and the crystal orientation is (30, 0, 0) degrees. The seam can be seen between the [1000] and [1100] zone axes.The master pattern's northern and southern hemispheres in stereographic projection, generated with EMsoft v5.0:
Don't know the reason for this issue, and don't have the time to look into it at the moment. Reported it here so we can deal with this at a later time.
The text was updated successfully, but these errors were encountered: