- What I did
cherrypick of: #246
fixes sonic-net/sonic-buildimage#9996
Handle error seen on system where vlan interface map is not present.
This change requires: sonic-net/sonic-py-swsssdk#117
On chassis platform, on supervisor there are not ports available in config_db. So, there is no vlan interface map in counters db, which causes this error in syslog:
- How I did it
Return empty dict if vlan interface map is not present in DB.
- How to verify it
With this fix, no error in syslog message.
Able to execute other MIB queries on supervisor.
UT passes.