Document RTU over TCP usage
Browse files Browse the repository at this point in the history
  • Loading branch information
andig committed Jan 2, 2020
1 parent 136c4b9 commit 909ac01
Showing 1 changed file with 11 additions and 2 deletions.
13 changes: 11 additions & 2 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -29,6 +29,7 @@ Modbus communication is possible over RS485 connections as well as TCP sockets.
You'll need:
* A supported Modbus/RTU smart meter OR an supported Modbus/TCP SunSpec-compatible grid inverter.
* In case of Modbus/RTU: A USB RS485 adapter. See [USB-ISO-RS485 project](https://github.com/gonium/usb-iso-rs485) for a home-grown adapter.
* Optionally an RS485 to Ethernet converter (see [SO discussion](https://stackoverflow.com/questions/59459877/is-rtu-over-tcp-a-spec-conforming-modbus-application))


## Installation
Expand Down Expand Up @@ -58,13 +59,21 @@ The full documentation is available in the [docs](docs/mbmd.md) folder.
A typical invocation looks like this:

$ ./bin/mbmd run -a /dev/ttyUSB0 -d janitza:26,sdm:1
2017/01/25 16:34:26 Connecting to RTU via /dev/ttyUSB0
2017/01/25 16:34:26 Starting API at :8080
2017/01/25 16:34:26 config: creating RTU connection via /dev/ttyUSB0 (9600baud, 8N1)
2017/01/25 16:34:26 httpd: starting api at :8080

This call queries a Janitza B23 meter with ID 26 and an Eastron SDM
meter at ID 1. Not all devices are by default configured to use ID 1.
The default device IDs depend on the meter type and documented in the meter's manual.

To use RTU devices with RS485/Ethernet adapters, add the `--rtu` switch to configure `mbmd` to use the TCP connection with RTU data format:

❯ ./bin/mbmd run -a rs485.fritz.box:23 --rtu -d sdm:1
2020/01/02 10:43:53 mbmd unknown version (unknown commit)
2020/01/02 10:43:53 config: creating RTU over TCP connection for rs485.fritz.box:23
2020/01/02 10:43:53 initialized device SDM1.1: {SDM Eastron SDM meters }
2020/01/02 10:43:53 httpd: starting api at :8080

If you use the ``-v`` commandline switch you can see
modbus traffic and the current readings on the command line. At
[http://localhost:8080](http://localhost:8080) you can see an embedded
Expand Down