Clarified paragraph regarding access to blocked zones #2

Merged
merged 1 commit into from
Jan 30, 2019
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
15 changes: 8 additions & 7 deletions rulebook.tex
Original file line number Diff line number Diff line change
Expand Up @@ -849,13 +849,14 @@ \subsubsection{Machine Positioning}
}
\label{fig:zone-mps-blocked}
\end{figure}
For placing of machines, the RefBox will take care of the necessary
constraints to ensure that all in- and output sides, shelves and
slides are reachable. If a machine is rotated with \ang{0}, \ang{90},
\ang{180} or \ang{270} the zones in front the input and output side
are blocked as well (\reffig{fig:zone-mps-rotation-straight}). For
machines with rotations \ang{45}, \ang{135}, \ang{225} and \ang{315}
three zones in front of each input and output side are blocked
For placing of machines, the RefBox will take care of the necessary constraints
to ensure that all in- and output sides, shelves and slides are reachable. That
is, a path to each blocked zone (see \reffig{fig:zone-mps-blocked}) must exist
from any unoccupied or blocked zone of the field. If a machine is rotated with
\ang{0}, \ang{90}, \ang{180} or \ang{270} the zones in front the input and
output side are blocked as well (\reffig{fig:zone-mps-rotation-straight}). For
machines with rotations \ang{45}, \ang{135}, \ang{225} and \ang{315} three zones
in front of each input and output side are blocked
(\reffig{fig:zone-mps-rotation-odd}). No MPS nor blocked zones for another MPS
may be placed in a blocked zone. All blocked zones of any MPS must be located
within the competition area. Furthermore, only two machines will ever be placed
Expand Down